426351/A
33
2
Disconnect the cNODE Micro from the cNODE
battery charger.
LED indicator status and troubleshooting
LED indicator
What it means
How to fix this
Flashing green
The battery is charging
Constant green
The battery is fully
charged
Flashing red
The following might
have occurred:
• the charger is not
connected to the
transponder
• failure in
charger/transponder
connection
• charger might be
faulty
Do the following:
• disconnect all cables and wait 1 minute before
reconnecting the cables and connect power supply to
mains (110 or 220 Vac).
If the LED indicator is still flashing red then the
following might have occurred:
• the charger might be faulty. Contact your local
Kongsberg Maritime office if this is the case.
Constant red
The following might
have occurred:
• the battery
temperature might be
outside the charging
specification
• possible battery failure
Do the following:
• the battery temperature is outside the specification
and needs to climatise before charging. (10 to 40°C)
• disconnect all cables and wait 1 minute before
reconnecting the cables and connect power supply to
mains (110 or 220 Vac).
If the LED indicator is still red then the following might
have occurred:
Summary of Contents for cNODE Micro