24
458122/B
Caution
Equalize the temperature of the cNODE MiniS LF to between 10 °C and 40 °C before
charging it.
For on-deck charging, use the cNODE battery charger only.
Never charge the battery unattended.
Procedure
1
Disconnect the on/off plug from the cNODE transponder.
2
Let the unit warm up or cool down to an ambient temperature of 10 °C to 40 °C
before charging.
3
Connect the battery charger plug (
B
) to the connector on the cNODE MiniS LF
marked CHARGE (
C
).
4
Connect the battery charger to mains (110 or 220 VAC).
5
Remove the power cord after charging, before removing the connector from the
cNODE MiniS LF.
Result
The LED indicator on the charger flashes green when charging. It normally takes about
30 seconds before the charging starts and the LED indicator starts flashing green after
connecting the cNODE battery charger to the mains. The battery will be charged within
1 hour. The LED indicator will stay green when fully charged.
The transponder is ready for use.
cNODE MiniS LF Instruction Manual
Summary of Contents for cNODE MiniS LF
Page 1: ...458122 B September 2022 Kongsberg Maritime AS cNODE MiniS LF Transponder Instruction Manual ...
Page 34: ...34 458122 B cNODE MiniS 17 180 Ti dimensions cNODE MiniS LF Instruction Manual ...
Page 35: ...458122 B 35 cNODE MiniS 17 S Ti dimensions Drawing file ...
Page 36: ...36 458122 B TDR50V St dimensions cNODE MiniS LF Instruction Manual ...
Page 37: ...458122 B 37 TDR50V Ti dimensions Drawing file ...
Page 38: ...38 458122 B Transducer guard dimensions cNODE MiniS LF Instruction Manual ...
Page 39: ...458122 B 39 Floating collar dimensions Drawing file ...
Page 56: ... 2022 Kongsberg Maritime ...