background image

10

418799/A

A

Transducer: Channel 1 - 2

B

Transducer: Channel 3

C

Transducer: Channel 4

D

Power

E

Ethernet

F

Ground

Procedure

1

Connect the DC cable from the power supply to the +12 Vdc socket.

2

Connect the provided grounding cable from the nearest grounding point to the
dedicated terminal on the EA440SP.

Further requirements

Voltage requirement

: 12 to 15 VDC, 5A.

Connecting the Ethernet cable from the
EA440SP to the computer

The Computer is connected to the Suitcase using a high speed Ethernet cable.

Context

Note

It is very important that a high quality Ethernet cable is used. You must use CAT-5E STP
(Shielded Twisted Pair) quality or better. Using cables with lower bandwidth capacity
will reduce the EA440SP performance.

A

B

C

D

E

F

A

Transducer: Channel 1 - 2

B

Transducer: Channel 3

C

Transducer: Channel 4

EA440SP Splashproof

Summary of Contents for EA440SP

Page 1: ...418799 A October 2016 Kongsberg Maritime AS EA440SP Splashproof Single beam hydrographic echo sounder Quick installation guide ...

Page 2: ...al applies must only be used for the purpose for which it was designed Improper use or maintenance may cause damage to the equipment and or injury to personnel The user must be familiar with the contents of the appropriate manuals before attempting to operate or work on the equipment Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation use or mainten...

Page 3: ...onnecting one or more transducers to the EA440SP 8 Connecting power and ground to the EA440SP 9 Connecting the Ethernet cable from the EA440SP to the computer 10 EA440SP Channel 1 and 2 transducer cable 11 EA440SP Channel 3 transducer cable 12 EA440SP Channel 4 transducer cable 12 Quick installation guide ...

Page 4: ...4 418799 A EA440SP Splashproof ...

Page 5: ... transducers to the EA440SP page 8 Connecting power and ground to the EA440SP page 9 Connecting the Ethernet cable from the EA440SP to the computer page 10 EA440SP Channel 1 and 2 transducer cable page 11 EA440SP Channel 3 transducer cable page 12 EA440SP Channel 4 transducer cable page 12 Cable layout and interconnections ...

Page 6: ...6 418799 A Cable plan The cables are part of the delivery with the main units C2 C1 C1 C1 C3 C4 CD020301_010_003 C C C A Computer B Suitcase C Transducer EA440SP Splashproof ...

Page 7: ...See comment 2 C4 Ethernet Suitcase Transducer See comment 2 Comments 1 The transducer cable is provided with the transducer 2 This cable is provided with the EA440SP delivery Identifying EA440SP cables on a project cable drawing The EA440SP is often a part of a project delivery For such deliveries project cable drawings are established to show all the main cables and how the various products inter...

Page 8: ...ansducer is connected to a 7 pin connector on the rear of the suitcase The connectors are part of the EA440SP delivery A B C D E F A Transducer Channel 1 2 B Transducer Channel 3 C Transducer Channel 4 D Power E Ethernet F Ground Check the license information to see which transducer to install where See the cable drawings for the pin out of the transducers and connectors EA440SP Splashproof ...

Page 9: ...necting power and ground to the EA440SP The Suitcase must be connected to a suitable power source and must be properly grounded Context The EA440SP must be powered by a separate power supply or battery A connector with crocodile clips for easy connection to a battery is provided A B C D E F Cable layout and interconnections ...

Page 10: ...requirements Voltage requirement 12 to 15 VDC 5A Connecting the Ethernet cable from the EA440SP to the computer The Computer is connected to the Suitcase using a high speed Ethernet cable Context Note It is very important that a high quality Ethernet cable is used You must use CAT 5E STP Shielded Twisted Pair quality or better Using cables with lower bandwidth capacity will reduce the EA440SP perf...

Page 11: ... it to the Suitcase using the plug provided CD0808_ 10_00 0 2 3 1 2 4 5 6 Channel 1 Channel 2 Channel 2 Channel 1 Outer screen The socket is located on the bottom of the suitcase The socket is made to fit an Amphenol Ecomate 6 pin connector The connector is part of the delivery Minimum cable requirements Not applicable If you need an extension cable contact your dealer or Kongsberg Maritime for su...

Page 12: ... suitcase The socket is made to fit an Amphenol Ecomate 6 pin connector The connector is part of the delivery Minimum cable requirements Not applicable If you need an extension cable contact your dealer or Kongsberg Maritime for support EA440SP Channel 4 transducer cable Once the transducer cable has been installed you can connect it to the Suitcase using the plug provided CD0808_ 10_00 0 4 3 1 2 ...

Page 13: ...se The socket is made to fit an Amphenol Ecomate 6 pin connector The connector is part of the delivery Minimum cable requirements Not applicable If you need an extension cable contact your dealer or Kongsberg Maritime for support Cable layout and interconnections ...

Page 14: ... 2016 Kongsberg Maritime ...

Reviews: