922-20207001/1.0
101
Remove Device
Click this button to remove the selected rotator from the
Rotators
list.
Test Device
Click this button to open the
Rotator Test
dialog box.
Device Properties
•
Name
Enter any name into this field to label the device.
•
Unit
Select the rotator model you have from the list.
•
Device Axis
Select one sonar axis if you are using a single-axis unit, or select two sonar
axes for a dual-axes unit.
There are three possible sonar axes. To view the orientation of each axis, click
System Configuration
→
Deployment
→
Mounting Offsets
and select each axis in
the
Rotators
section. Observe the animation to see the rotation of each axis.
•
Port Location
Select which port the rotator is connected to — can either be a COM port or
a Sonar port.
•
Port#
This drop-down lists the available port numbers. Select the port where the
device is connected.
•
Baud Rate
Specify the baud rate (“speed”) for the serial communication.
•
Data Bits
Select the number of data bits for the serial communication.
•
Parity
Specify the parity for the serial communication.
Note
If required, a parity bit is used in a simple error detection algorithm for a serial
port.
•
Stop Bits
This parameter is used to indicate the end of the transmission. It is usually
set to
1
.