922-20207011/1.0
29
Procedure
1
Put the Sonar Head (D) onto a stable, flat surface.
Observe the four mounting holes provided on the top surface of the Sonar Head.
2
Put the plastic isolation pad (C) on top of the Sonar Head, lining it up with the
mounting holes.
3
Insert the plastic shoulder washers (A) into the four corresponding holes on top of
your bracket.
4
Put the bracket on top of the Sonar Head, lining it up with the mounting holes.
Note
Ensure the Sonar Head connector is pointing in the right direction (so that the cable
connecting the Sonar Head to the other system units is routed correctly).
5
Secure the Sonar Head to the bracket (B) with the provided short screws.
Caution
Marine grade grease or anti-seize compound (included) must be applied to all
fasteners during assembly. Do not use excessive force when tightening the screws or
the threads will permanently be damaged.
Related topics
Installing the sacrificial anode, page 30
Mounting the Sonar Head, page 32
Summary of Contents for Flexview