HiPAP Model 501/451/351/101
52
317748/F
HiPAP 501 Performance
(Cd31184)
The figure above shows the accuracy as a function of signal to
noise ratio. The elevation and the orthogonal angles are 0
(at
vertical).
HiPAP® 451
The HiPAP® 500 transducer is used, and it has the same
technical performance as the HiPAP® 351.
Refer to HiPAP® 351 SSBL accuracy.
HiPAP® 351
HiPAP
®
351/451
Single system
S/N [dB rel. 1
Pa]
20
10
0
Angular Accuracy, 1
[
]
(At 0
elevation)
0.18
0.23
0.4
Range Accuracy, 1
[m]
0.1
0.15
0.2
Cymbal Range Accuracy,
1
[m]
0.02
0.02
0.02
Receiver beam [
]
15
Coverage [
]
+/-80
The elevation and orthogonal angles are used in the accuracy
curves.
Summary of Contents for HiPAP 101