KONGSBERG K-Sync
Figure 5
System settings - K-SYNC Status
Network settings
The
Synchronizing unit IP address
is entered in the
System settings
dialog. This setting
must match the IP address of the synchronizing unit for the application to connect.
The IP address of the synchronizing unit is specified here. This address should
normally be 157.237.60.169, unless the synchronizing unit IP was set differently during
installation (see
Installation Manual
). After changing the IP address in the K-Sync
application, the application should be restarted and one should verify that communication
with synchronizing unit is functioning (LED in system control turns green or yellow).
Depth datagram input
The Synchronizing Unit can receive depth data from external sources. Depth data is sent
as datagrams directly to the Synchronizing Unit.
In order to receive depth externally, a network switch must be interfaced between the
Workstation and the Synchronizing Unit as the latter has only one Ethernet connection.
The
UDP receive port
for receiving depth datagrams can be modified to any value equal
or greater than 1024 and less than 65535.
16
342435/B