Table 2
LED description
System control
System state
Description of state
(LED is red)
Not connected
K-Sync Application has
not yet connected to the
Synchronizing Unit. Status
in the user interface is not
updating and is grayed out.
(LED is yellow and
blinking)
Paused
Synchronization is paused
(yellow LED is blinking).
Trigger display updates
current signal levels and
echo sounder states, but
no echo sounder is being
triggered by Synchronizing
Unit. Clicking button will
enable running state.
(LED is green)
Running
System is running and all
enabled and scheduled
echo sounders are being
triggered. Clicking button
will enable paused state.
The default state when the system is powered up and connected is paused mode. When
paused, trigger display updates, but no synchronization takes place and no echo sounder
is triggered. To start triggering click the toggle button and it will change to Running.
No echo sounder will be triggered until they have been enabled and assigned to trigger
groups. These settings will be explained later in this chapter.
In the case the K-Sync Application loses the connection with the Synchronizing Unit, the
LED will again turn red.
If the Workstation becomes disconnected (intentionally or if network connection fails),
the Synchronizing Unit will continue to operate as before. The application will stop
updating the status and the system control LED will turn red. When system reconnects,
the K-Sync Application will return to the same state (running or paused) as before the
system became disconnected and the current mode will be conveyed in the user interface.
System status and manual depth setting
The system status provides information about incoming depth data and status/error
messages from the Synchronizing Unit. Also, current depth can be overridden with a
manual value, by enabling the Use manual depth checkbox as seen in figure
on page 36.