10. System Sub-Menu - continued
DIspLAy ADDREss
: As mentioned previously, every device has a unique address and the
Engine Monitor is no different. In single engine setups the default display address is 40 (SAE
recommendation). If the Engine Monitor does not display all necessary data (which is supported)
please contact your engine manufacturer for advice on the value of this setting.
ALARM FILTER:
This setting specifies whether the Engine Monitor will monitor and display
alarms from all sources (GLB, global) or only the source address’ specified in the settings Source
Address 1 & 2 (SRC, source).
spn VERsIOn:
Set the Suspect Parameter Number [Version 1, 2 or 3]. Version 4 is
automatically detected, but older engines will have to be set to 1, 2 or 3.
Note. Consult your engine supplier to establish which SPN version is appropriate if you have
problems reading alarm data.
J1587 sETTIngs:
This screen allows adjustments specific
to the J1587 Datalink.
sOURcE ADDREss 1 & 2:
J1587 supports source
addresses in the form of the MID (Message ID) and has values
defined from 128 (Engine 1) to 250 (Steering Column Unit) with
all other values reserved. 255 is a special case, it indicates all
data from all sources in its raw data form. Source Address 1
defaults to 128 and Source Address 2 defaults to 130.
DIspLAy ADDREss:
The display address allows values from 128-255.
ALARM FILTER:
This setting specifies whether the Engine Monitor will monitor and display
alarms from all sources (GLB, global) or only the source address’ specified in the settings
Source Address 1 & 2 (SRC, source).
page 24