922-20297011/1.0
55
Making sure that all M3 Sonar FLS system cables are properly
connected
The M3 Sonar FLS relies on communication between each system unit, and between the M3
Sonar FLS and external devices. It is very important that all cables are correctly installed,
that the proper cable types have been used, and that all cables are connected correctly.
Prerequisites
• All M3 Sonar FLS hardware units have been installed according to the relevant
instructions.
• All system cables have been installed.
• All connections have been made.
• All operating power is available.
• Two people with two-way communication devices are required to check the cable cores
(if applicable).
• You will need an ohmmeter to verify electrical connections and for continuity testing.
• To check the cable cores, you will need a suitable shorting strap.
Procedure
1
For each cable that is in used on the M3 Sonar FLS:
a
Verify that the cable has been installed according to the cable plan.
b
Verify that the connections made at each end of the cable are correct.
c
Verify that any locally-fitted plugs and connectors are suitable for the installation
location.
For example, sealed or spark-proof connectors should be used in areas where
flammable gasses may accumulate.
d
Check that the cables are secured and do not represent a trip hazard.
e
Ensure that all cables are correctly laid in conduits, or are otherwise protected
according to the regulations and recommendations laid down by the vessel’s
registering authority.
f
Ensure that all connections are tight and secure and that any protective covers
are fastened correctly.
2
If applicable, verify that each cable core has the correct connection and continuity.
Note
Two people are required for this procedure. You use the ohmmeter, and the other
person uses the shorting strap.
Summary of Contents for M3 Sonar FLS
Page 1: ...Installation Manual M3 Sonar FLS Forward Looking Multibeam sonar ...
Page 2: ......
Page 8: ...6 922 20297011 1 0 M3 Sonar FLS ...
Page 72: ...70 922 20297011 1 0 Sonar Head outline dimensions M3 Sonar FLS Installation Manual ...
Page 73: ...922 20297011 1 0 71 Drawing file ...
Page 97: ......
Page 98: ... 2020 Kongsberg Mesotech ...