922-20297011/1.0
77
•
Computer Time Sync
If ZDA is configured, the M3 Sonar FLS software will use the time in the ZDA message
to synchronize the computer clock automatically in the background. However, you may
need to run the M3 Sonar FLS software as an administrator (right-click on the icon
and select
Run as administrator
) or Windows may not allow the software to change the
system clock. Computer time sync can be useful when data is being logged on more than
one computer and synchronized timing is required. This method is not recommended
for Bathymetry applications as it is not accurate enough.
Note
Computer time sync requires both GGA and ZDA input.
Performance specifications
These performance specifications summarize the main functional and operational
characteristics of the M3 Sonar FLS system.
•
Range
: 0.2 m to 200 m
•
Coverage
: 200°
•
Range resolution
: 1 cm
•
Frequencies
: 175 kHz, 190 kHz, 200 kHz, 225 kHz
•
Pulse types
: CW, CHIRP
•
Mode
: Imaging
•
Communication
: Ethernet
•
Data Rates
: 10/100 Mbps
Synchronization
•
PRI Synchronization (master / slave operation):
–
Sync Input
: 0 to 5 VDC, hold-off when high
–
Sync Output
: 0 to 5VDC active low pulse 100μs
Summary of Contents for M3 Sonar FLS
Page 1: ...Installation Manual M3 Sonar FLS Forward Looking Multibeam sonar ...
Page 2: ......
Page 8: ...6 922 20297011 1 0 M3 Sonar FLS ...
Page 72: ...70 922 20297011 1 0 Sonar Head outline dimensions M3 Sonar FLS Installation Manual ...
Page 73: ...922 20297011 1 0 71 Drawing file ...
Page 97: ......
Page 98: ... 2020 Kongsberg Mesotech ...