80
922-20297011/1.0
Minimum computer requirements
Although a computer can be ordered from Kongsberg Mesotech as a part of the M3 Sonar
FLS delivery, it is also possible to purchase one locally.
If you purchase a computer locally, make sure that the chosen model meets the functional
and technical requirements.
It is important to make sure that the chosen computer model is relatively new with sufficient
processing power, a high performance graphic adapter, and a high speed network adapter.
We recommend a computer with a CPU that has a PassMark Software benchmark score
of 8000 or more (
).
PassMark Software is a Windows computer performance benchmarking utility. Computers
with a CPU score of 8000 or higher have been tested with the M3 Sonar FLS. Lower-scoring
computers may not perform well, resulting in a slow GUI response, slower ping rates, or
dropped pings.
When running two M3 Sonar FLS Sonars, an average CPU Mark of 10,000 is recommended.
The computer must be able to facilitate the various interface requirements made by the M3
Sonar FLS, and you may need to add extra Ethernet and serial adapters.
Note
The computer design and construction must allow for maritime use, easy access to
connectors, parts and cables, and a safe installation.
The minimum technical requirements are:
•
Processor
: 2.80 GHz, Intel quad core i7
•
Memory
: minimum 8 GB
•
Hard disk
: minimum 500 GB
•
Graphics card RAM
: 256 MB
•
Network interface
: 100/1000 Mbps
•
Serial interfaces
: One or more serial line interfaces are required. The number of serial
lines depends on the interface requirements.
•
Operating system
: The M3 Sonar FLS software has been designed for the Microsoft
®
64-bit Windows 10 operating system. Windows 7 is supported for imaging applications
only. Profiling applications will not work properly in Windows 7. Operating systems
older than Windows 7 are not supported.
M3 Sonar FLS Installation Manual
Summary of Contents for M3 Sonar FLS
Page 1: ...Installation Manual M3 Sonar FLS Forward Looking Multibeam sonar ...
Page 2: ......
Page 8: ...6 922 20297011 1 0 M3 Sonar FLS ...
Page 72: ...70 922 20297011 1 0 Sonar Head outline dimensions M3 Sonar FLS Installation Manual ...
Page 73: ...922 20297011 1 0 71 Drawing file ...
Page 97: ......
Page 98: ... 2020 Kongsberg Mesotech ...