218
442700/A
Inserting the installation parameters for the transducer
When the installation trunk is mounted, it may not be positioned with the mounting holes
perfectly aligned to the centre line of the vessel. When the hull unit is placed on the trunk,
the "forward" mark on the transducer shaft sleeve - and thus also "forward" on the transducer
- may not point forward at all, but several degrees off the centre line. To obtain accurate echo
presentations, this misalignment must be adjusted by changing the installation parameters.
Prerequisites
Illustration
CS90
:
A
Bow
B
This is the alignment angle (±180°)
C
0° transducer mark
The CS90 system has been set up with
its hardware units connected as specified
in the
Installation Manual
.
• The CS90 system is turned on and
operates normally.
• The CS90 system is in
Normal
mode,
but
TX Power
is set to
Off
to prevent
transmissions.
• The vessel is berthed or at sea.
• Neither tools nor instruments are
required.
For accurate location of the transducer,
you need the detailed vessel drawings. You also need the installation angles that were
recorded when the transducer was installed.
Simrad CS90 Reference Manual
Summary of Contents for Simrad CS90