154
394149/D
Single beam low power transducer connection to a circular
transducer socket
Maximum four single beam low power transducers can be connected to terminals
A
through
J
on the circular 12-pin Amphenol transducer socket (Type 97-12-19S). This
socket is used on the General Purpose Transceiver (GPT), and on several versions of the
Wide Band Transceiver (WBT).
The other end of the cable is permanently fixed to the transducer.
A
Transducers
B
License identification
C
Connectors on the 12-pin Amphenol socket
D
Circular 12-pin Amphenol socket (As seen towards the socket (face view))
The cable screen must be connected to the housing on the transducer plug.
Note
The black wires in the transducer cable are not for grounding. You must never connect
these together. You must never connect any of them to vessel ground.
If you need to extend the transducer cable, you must splice it correctly. This is very
important, as any splice is very vulnerable for noise. Cable can be spliced using two
different methods:
• Splicing using a grounded junction box
• Splicing using a junction box that is isolated from vessel’s ground
Refer to the dedicated procedures.
We strongly recommend that you install the transducer cable in a steel conduit.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...