Kongsberg Simrad EM 300
Base version
182
160719
/F
The
Sounder Beam Width
parameter value depends on the type
of transducer used for the EA500. It varies with the frequency, and
is a fixed value that may be found in the product specification of
the installed EA500 echo sounder.
Common
In this field, you can select options associated with the whole Ping
Display.
Sampling rate -
Use this control to define how often the Ping
Display fetches a datagram to update the displays.
Display Update Frequency -
Use this control to set the frequency
at which the displays are updated on the screen.
Window Orientation -
This selector controls the overall
organization of the Ping Display.
•
Vertical: The three charts will be stacked on top of each other.
•
Horizontal: The three charts will be placed side by side
horizontally.
Fonts in Graphs -
Use this control to define the character size used
in the displays.
Depth Displays
This is used to change the automatic scaling when spiky data gives
a noisy display. The
Depth Displays
field contains the
Depth
Delta Parameter
as a slider. To change the
Depth Delta
slider,
drag it to the wanted value and release. The new value will be used
immediately for all subsequent pings. The
Depth Displays
field
also contains
Rescale after N Pings
as a slider. This slider lets you
rescale after a certain number of pings.
Heave / Height Delta
This is used to change the automatic scaling when spiky data gives
a noisy display. The
Heave / Height Delta
field contains the
Heave / Height Delta Parameter
as a slider. To change the
Heave
/ Height Delta
slider, drag it to the wanted value and release. The
new value will be used immediately for all sensor buffer contents.
Heave - Height Alarm Offset
In this field you can set the value
Height Delta (m)
with the slider.
The
Height Delta
is the difference in meters between heave and
height. You will then be notified when the difference between
heave and height is greater than your chosen value.
Scope
This field allows you to control the presentation of the
Scope
Display
. The following options are available:
Summary of Contents for Simrad EM 300
Page 1: ...EM 300 Multibeam echo sounder Base version Operator manual ...
Page 2: ......
Page 20: ...Kongsberg Simrad EM 300 Base version XVI 160719 F Blank page ...
Page 286: ...Kongsberg Simrad EM 300 Base version 266 160719 F Figure 96 Calibration main window ...
Page 306: ...Kongsberg Simrad EM 300 Base version 286 160719 F Help The Help option provides on line help ...
Page 321: ...Planning 301 160719 F Figure 107 Creating parallel lines ...
Page 369: ...Sound Speed Profile Editor 349 160719 F Help This opens the online help system ...
Page 405: ...Operation manual 385 160719 F Blank page ...
Page 406: ...Operation manual 386 160719 F Blank page ...
Page 408: ...Blank page ...