18
922-00047001/1.1
K
High Voltage start button
L
Cable connector for test cable
M
Ethernet connector for test connection
There is a power switch on the back of the Surface Telemetry Unit, and a power button on
the front. Both must be turned on.
However, during normal operation, you only need to use the button on the front to turn
the unit on and off.
Note
After powering up the FM90i, there will be a brief delay before the Processor Unit discovers
the Sonar Head. The length of this delay depends on external factors, such as the length of
your netsounder (third-wire) cable. Wait for the
LINK
LED (H) on the Surface Telemetry
Unit to turn solid before attempting to connect to the Sonar Head.
Procedure
1
On the back of the Surface Telemetry Unit, turn the power switch on.
2
On the front of the Surface Telemetry Unit, press the
PWR
button (A).
Observe that the blue LED ring on the
PWR
button flashes.
3
Turn on the display.
If required, refer to the instructions provided by the display manufacturer.
4
Turn on the computer.
Wait while the operating system loads.
5
On the computer desktop, double-click the FX icon to start the program.
Note
The program is not automatically started when the computer is turned on.
6
Once the program has started, observe that the display presentation fills the entire
screen.
The program starts up using the same settings as the last time you used it. If these
settings are acceptable, continue operation. If you wish to alter any of the settings, see
the relevant procedures.
Simrad FM90i Reference Manual