322
476671/B
b
Set
Start sample
to
50
c
Set
Sample range
to
2000
d
Look at the pattern in the B-Scan presentation, and compare them with the
example provided.
This screen capture shows the B-Scan pattern while testing the transmitter. You
can clearly see the transmit pulse.
9
Make sure that there are no weak elements in the transmission sample range.
If any weak elements are detected, record these in the result table.
10
Make sure there are no black lines in the transmission and reception sample range.
A black line indicates an unserviceable transducer element. If any such elements are
detected, record these in the result table.
11
Finish the test.
a
Close the
Element BITE
(Element Built-In Test Equipment) dialog box.
b
Close the
Diagnostics
dialog box.
c
Set
Tx Power
to
Off
.
d
Set
Operation
to
Inactive
.
e
Hoist the transducer back up to its upper position.
Simrad MF90 Installation Manual
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...