64
476671/B
Related topics
Sonar room requirements, page 62
Preparations, page 42
Size and access requirements
A well designed sonar room with a well fitted size and easy access reduces the risk of
corrosion, and simplifies maintenance. This increases system reliability.
Note
The physical size of the sonar room must be limited, so that in the event of a major leak, the
flooding of the room will not induce instability, or cause the vessel to capsize or sink.
The sonar room must be large enough to house all the system units. The room must provide
enough space to allow efficient maintenance. You must be able to keep all the cabinet doors
fully open without undue restriction to your movements.
1
The room must not be used for any other heavy machinery.
2
The room must not be unnecessarily obstructed by girders, pipes etc, which may cause
installation problems or impede maintenance.
3
The sonar room must be accessible under all conditions at sea or at a berth.
4
All doors or hatches must be designed so that the tools and equipment can be removed
without being disassembled.
5
All cables leading in and out of the sonar room must be run in steel conduits. These
steel conduits must reach up and above the freeboard deck.
6
In the event of a major leak, it must be possible to close all watertight hatches and/or
doors to the room to maintain vessel stability and safety.
Note
The physical distances between the various system units are limited by the length of the
cables. Make sure that all the cables are installed in such manners that the transducer can
be lowered and hoisted without damaging them.
Related topics
Sonar room requirements, page 62
Preparations, page 42
Simrad MF90 Installation Manual
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...