442704/A
489
The filters in the ST90 system are implemented in “series”. The noise filtering is done
early in the receiver process.
A
Bottom Filter
B
Noise Filter (1)
C
Gain & TVG (Time Variable Gain)
D
Noise Filter (2)
E
AGC (Automatic Gain Control)
F
RCG (Reverberation Controlled Gain)
G
Display Gain
H
Ping-Ping Filter
Note that
Gain
,
TVG
(Time Varied Gain) and
Display Gain
are not filters, but included
only to illustrate the complete "signal path".
Details
Off
Choose this setting to switch the filter off.
Weak
The system starts using one amplifier stage and increases the number as a function
of range.
Medium
The system starts using two amplifier stages and increases the number as a function
of range.
Strong
The system starts using three amplifier stages and increases the number as a function
of range.