Description
In the B-Scan presentation, each element in the transducer is shown as a long coloured
vertical rectangle. If you place the cursor on top of one of these rectangles, a small yellow
tool-tip will identify key information about the channel.
• The identification of the transducer element
• The identification of the transceiver board
• The current sample you are looking at
• The measured echo value (in dB)
Tip
To detect unserviceable transducer elements and/or transceiver boards, you must
compare the rectangles. When operating the ST90 system in port, the colours will be
less homogeneous due to the environmental noise and the shallow depth. During normal
operation at sea the colours will be homogeneous.
• If a single element is "dead" (no transmit, no receive), the rectangle is easily spotted
because its colour is black.
• If a single element is receiving, but not transmitting, the rectangle is normally presented
in lighter shades of blue.
• If a transceiver board is "dead" (no transmit, no receive), all the transducer elements
connected to the board are easily spotted because they are all black.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...