• Ethernet switch
Make sure that your selected Ethernet switch has a large bandwidth capacity. Minimum 1
Gb (1000BASE-T) is required.
• Ethernet cables
It is very important that high-quality Ethernet cables are used. You must use CAT-5E
STP (Shielded Twisted Pair) quality or better.
Neither tools nor instruments are required.
Context
When supplied, the Operating Panel is set up with the following communication parameters:
• IP Address: 157.237.60.20
• Subnet mask: 255.255.255.0
• Gateway: 157.237.60.1
The IP and MAC addresses for your Processor Unit are contained in a text file named
IPandMACaddress.txt
. The file contains the product name, IP address and MAC address in
the following format (example):
ST90
157.237.60.14
AC:1F:6B:1D:42:E6
Tip
If the distance between the Processor Unit and your second display is considerable, we
suggest that you use KVM (Keyboard Video Mouse) technology to preserve the video quality.
Procedure
1
Make the following preparations.
a
On the Processor Unit, close any programs that are running, and return to the
desktop.
b
Insert the Ethernet switch between the Operating Panel and the Processor Unit.
Make sure that you use the correct Ethernet socket on the rear side of the
computer: ETH1
c
Install the secondary Operating Panel.
d
Connect the Operating Panel to AC mains.
e
Connect the power cable from the Ethernet switch to the AC power outlet.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...