Motor mounting instructions

Motor Specifications:

Model FRL 10 Blower/Aspirator 

fans are designed to be driven by 

Single or 3 phase, TEFC Electric 

Motors with a Horse Power Rating 

of 1.5 HP at 3500 RPM. and with a 

Frame Spec. of NEMA 56C Flange. 

(Shaft Dia. = 5/8", Shaft Length = 

1 7/8", Key Size 3/16"sq. x 1 1/8" 

long).

(Kongskilde FRL 10 Blowers are 

also available fully assembled with 

motors, see dealer for details and 

motor options).

Motor Shaft Drilling.

Note: Prior to assembling the 

blower housing and rotor to the mo-

tor, the motor shaft must be drilled 

and tapped to accept a 5/16"-18 

UNC x 3/4" bolt and washers. (In 

some instances, motors supplied 

by the factory may have the shafts 

pre-drilled and tapped for an M8 x 

20 mm Metric Bolt). Please refer to 

assembly instructions and diagram 

Detail A.

Note: It is very important to drill 

and tap the motor shaft and to 

secure the rotor to the shaft with 

the bolt and washers as de

-

scribed in the assembly instruc

-

tions.

Assembly Instruc-

tions.

Refer to assembly diagram.

1  Place the half housing on to 

the motor flange and rotate the 

housing to align the bolt holes. 

 

Note:

 Take care to consider 

what position is best for access 

to the motor wiring box when the 

blower is installed.

2  Mount the half housing to the 

motor with four 3/8" x 3/4" bolts 

and 3/8" lockwashers and tight-

en the bolts.

3  Install the fan rotor all the way 

on the motor shaft and insert the 

key.

4  If the motor shaft extends be-

yond the end of the rotor, install 

a 5/8" x 1 1/4" x 1/4" spacer 

bushing over the end of the 

shaft. If the motor shaft does not 

extend past the rotor the spacer 

will not be needed. 

 

Note:

 In some cases you may 

need to shorten the key in order 

to allow the spacer to sit flush 

against the rotor busing.

5  Install the 5/16" (or M8) bolt, 

with both a large washer and 

lockwasher, in the end of the 

motor shaft and tighten.

6  Install the outer half housing 

over the rotor and attach the 

blower housings together with 

two M6 x 12 mm screws, serrat-

ed washers and nuts. Place one 

bolt in the hole nearest to the 

blower outlet on each side of the 

housing.

7  Install the bolt tightener bracket 

on the bottom side of the blower 

housing with the M6 x 16 mm 

screw, serrated washer and nut.

8  Install the housing clamp with 

the M6 x 16 mm screw, serrat-

ed washer and nut. Start at the 

fixed end on the top side of the 

fan housing, and carefully wrap 

the clamp around the seam to 

seal the housings together.

9  Insert the M8 x 70 mm tightener 

bolt with 1 washer, through the 

tightener bracket and the end 

of the housing clamp. Install a 

second washer and secure with 

nut.

10 Slowly draw the clamp around 

the housing with the tightener 

bolt. 

 

Note:

 Lightly tap the clamp with 

a rubber mallet along the edge 

of the seam to firmly seal the 

housings together and secure 

the bolt and nut.

11 If the fan inlet will be exposed 

during operation install the fin

-

ger guard grill with the OK160 

bolt clamp provided. 

 

Note:

 If optional stand is used 

- attach stand to blower then 

install finger guard grill to the 

stand with OK160 clamp pro-

vided.

Summary of Contents for FRL 10

Page 1: ...FRL 10 Centrifugal blowers Manual ...

Page 2: ...4 If the motor shaft extends be yond the end of the rotor install a 5 8 x 1 1 4 x 1 4 spacer bushing over the end of the shaft If the motor shaft does not extend past the rotor the spacer will not be needed Note In some cases you may need to shorten the key in order to allow the spacer to sit flush against the rotor busing 5 Install the 5 16 or M8 bolt with both a large washer and lockwasher in th...

Page 3: ...3 ...

Page 4: ...l times Never look or place hands into the airstream blower outlet or other air material discharge points to check for restrictions Never insert anything into the blower inlet or outlet to clean or dislodge foreign material from the fan rotor Always disconnect the blower from the power sup ply and check to insure that the rotor has come to a complete stop before cleaning or servicing the unit ...

Page 5: ...5 ...

Page 6: ...re 11 131 013 018 Rotor Standard FRL10 D 265 mm d 5 8 bore 12 131 011 049 Bolt bracket plated 13 100 323 002 Round head screw M8 x 70 mm 14 100 315 012 Nut M8 15 131 011 011 Housing clamp 16 100 321 015 Screw M6 x 15 mm 17 121 220 256 Spacer bushing 5 8 I D x 1 1 4 O D x 1 4 THK Not always used 18 100 331 005 Washer M8 19 100 332 003 Star washer M8 20 100 304 012 Set screw M8 x 20 mm 100 356 108 S...

Page 7: ...7 ...

Page 8: ...80 Sorø Tel 45 72 17 60 00 mail kongskilde industries com www kongskilde industries com www kongskilde grain com 121 220 270 You can always find the latest version of the manuals at 12 04 2019 www kongskilde industries com www kongskilde grain com ...

Reviews: