8
GB
These operating instructions ap-
ply to Kongskilde Multiair blowers
model 1000.
Application
Kongskilde Multiair blowers are
designed for use in connec tion with
pneumatic conveyors.
No materials must be allowed to
pass through the fan.
The Multiair blowers are not intend-
ed for corrosive gases, and the air
temperature must not exceed 70°C.
Safety
- See that all protection caps are
intact and pro perly secured dur
-
ing operation.
- Always stop the blower prior
to repair and maintenance and
avoid unintentional start of op-
eration.
- Never put your hand into the
inlet or outlet opening of the
blower during operation.
- If the blower is to be moved,
use a fork-lift or the like grab-
bing under the base frame of the
blower.
Wiring
Check that the local mains supply
meets the motor and electric equip-
ment specifications.
Wiring must be effected by a certi
-
fied electrician.
The direction of rotation of the
blower rotor should be clock wise
viewed from the inlet side.
Installation
The Multiair blower is supplied from
the factory ready for use and only
requires connection to the mains
supply and pipelines.
Mount the blower on a solid and
plane base.
Allow during erection for easy ac
-
cess for repair and main-tenan ce.
Mount the mounting flanges under
the blower. Adjust the mounting
flanges under the blower to provide
uniform support.
See that there is unimpeded access
for cooling air to the room housing
the blower. The blower is designed
for max. 40°C cooling air.
Start and stop
Start and stop the blower in accord-
ance with the instruction for the
electric equipment.
Maintenance
In case of abnormal noise or vibra-
tions, stop the blower and repair the
defect before restarting the blower.
Lubrication
The blower bearings are lubricated
from the factory and require no
further maintenance.
Cleaning
Always ensure unimpeded ac
-
cess of cooling air to and from the
blower.