1 - 27
25 ADJUSTMENT
88
57
Numbering
99999999
89
58
Set quantity 1
99999999
90
59
Set quantity 2-5
99999999
91
5A
Set quantity 6-10
99999999
92
5B
Set quantity 11 or more
99999999
93
5C
Time while power remote 1 is on
99999999
Total period of time dur-
ing which image control
board is energized (re-
mote power supply 1 is
ON). 1 is counted per
minute. This value is
written into non-volatile
memory at power-off.
945D
Time while power remote 2 is on
99999999
Total period of time dur-
ing which remote power
supply 2 is ON. 1 is
counted per minute. This
value is written into non-
volatile memory when
image control is turned
OFF.
95
5E
Time while power remote3 is on
99999999
Total period of time dur-
ing which remote power
supply 2 is ON and 24 V
relay is ON. The count is
incremented by 1 per
minute. This value is writ-
ten into non-volatile
memory when image
control is turned OFF.
96
5F
Time while power remote 4 is on
99999999
Total period of time dur-
ing which remote power
supply 3 is ON. The
count is incremented by
1 per minute. This value
is written into non-volatile
memory when image
control is turned OFF.
97
60
Time during low power mode
99999999
Total period of time dur-
ing which low power
mode is selected. The
count is incremented by
1 per minute.
NO
KRDS
Item
Maximum
Counting condition
parameter
(F1)
count
METHOD
REPLACEMENT
MODEL
7075/7085
MANUAL
SERVICE HANDBOOK
REVISED EDITION
3
DATE
Jan. 2002
PAGE
1-27
3
Summary of Contents for 7075/FORCE 75
Page 1: ...FEBRUARY 2003 CSM 7075 F75 7085 F85 SERVICE MANUAL MODELS 7075 FORCE 75 7085 FORCE 85...
Page 2: ......
Page 3: ...7075 FORCE 75 7085 FORCE 85 SERVICE MANUAL FEBRUARY 2003...
Page 39: ...OUTLINE 1...
Page 40: ...Blank page...
Page 55: ...1 15 MAIN BODY 11 Paper Exit Drive Section FRONT Paper exit roller Paper exit motor M10...
Page 58: ...1 18 MAIN BODY 14 Web Drive Section FRONT Web drive motor M16 Cleaning web...
Page 59: ...UNIT EXPLANATION 2...
Page 60: ...Blank page...
Page 62: ...2 A 2 EXTERNAL SECTION Blank page...
Page 120: ...2 K 6 TRAY 3 PAPER FEED UNIT Blank page...
Page 126: ...2 L 6 BY PASS TRAY Blank page...
Page 130: ...2 M 4 VERTICAL PAPER CONVEYANCE SECTION Blank page...
Page 154: ...2 O 8 FIXING UNIT Blank page...
Page 165: ...DISASSEMBLY ASSEMBLY 3...
Page 216: ...3 H 4 TONER SUPPLY UNIT Blank page...
Page 224: ...3 I 8 CLEANING TONER RECYCLE UNIT Blank page...
Page 232: ...3 J 8 PAPER FEED UNITS OF TRAYS 1 AND 2 Blank page...
Page 240: ...3 K 8 TRAY 3 PAPER FEED UNIT Blank page...
Page 292: ...3 O 18 FIXING UNIT Blank page 3 O 16...
Page 293: ...MODELS 7075 FORCE 75 7085 FORCE 85 SERVICE SECTION FEBRUARY 2003...
Page 294: ......
Page 315: ...ADJUSTMENT 1...
Page 316: ......
Page 343: ...1 19 25 ADJUSTMENT Blank page 1 19 2...
Page 372: ...1 44 25 ADJUSTMENT 1 ADJUSTMENT Blank page...
Page 458: ...1 114 OTHER ADJUSTMENT Blank page 1 112 2...
Page 497: ...ISW 2...
Page 498: ......
Page 511: ...SERVICE 3...
Page 512: ......
Page 514: ...Blank page...
Page 550: ...3 18 SERVICE Blank page...
Page 551: ...ELECTRICAL PARTS LIST WIRING DIAGRAMS 4...
Page 552: ......
Page 611: ...JAM ERROR CODE LIST 5...
Page 612: ......
Page 625: ...5 13 JAM CODE LIST Blank page 5 11 2...
Page 659: ...TIMING CHARTS 6...
Page 660: ......
Page 678: ...6 18 TIMING CHARTS Blank page...
Page 679: ...INSTALLATION INSTRUCTIONS 7...
Page 680: ......
Page 692: ...Blank page...
Page 704: ...Blank page...
Page 724: ...Blank page...
Page 730: ...Blank page...
Page 736: ...Blank page...
Page 758: ...Blank page...
Page 780: ...Blank page...
Page 832: ...Blank page...
Page 833: ...APPENDIX 7085 OVERALL WIRING DIAGRAM...
Page 834: ......