background image

Innovative 45/0 geometry optics

Most lightweight, compact and rugged in its class

360-740 nm wavelength range, 10 nm resolution

Single-handed operation with "Navigation wheel"

Free choice of power source : AC adapter or AA batteries

Color Data Software

Supports Windows

®

2000/XP

Model

Spectrophotometer CM-2500c

Illumination/observation system

45/0 method (45

°

ring-shaped illumination, vertical viewing)

Light-receiving element

Silicon photodiode array (dual 40 elements)

Spectral separation device

Diffraction grating

Wavelength range

360 nm to 740 nm

Wavelength pitch

10 nm

Half bandwidth

Approx. 10 nm

Reflectance range

0 to 175%, resolution: 0.01%

Light source

2 pulsed xenon lamps

Measurement time

Approx. 1.5 seconds

Minimum interval between measurements

4 seconds

Battery performance

Alkaline manganese: Approx. 1000 measurements, (at 23

°

C)

Measurement/illumination area

ø7 mm/ø11 mm

Repeatability

Colorimetric Value: Standard deviation within

E*ab 0.05

(Measurement conditions: White calibration platemeasured
30 times at 10-second intervals after white calibration was
performed)

Inter instrument agreement

Within

E*ab 0.25

(Average for 12 BCRA Series II color tiles compared to values
measured with master body; at 23

°

C)

Measurement mode

Single measurement/automatic averaging of multiple
measurements (auto mode: 3, 5, 8 times/manual mode)

Interface

RS-232C standard

Observer

2/10 degrees (CIE 1931/2

°

, CIE 1964/10

°

)

Illuminant

A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12
(simultaneous evaluation is possible using two light sources)

Display data

Spectral value/graph, colorimetric value, color difference
value/graph, PASS/FAIL result,
ASSESSMENTS (Except for Japanese mode)

Color space/colorimetric data

L*a*b*, L*C*h, CMC(1:1), CMC(2:1), CIE94, Hunter Lab, Yxy, Munsell,
XYZ, MI, WI (ASTM E313), WI (CIE), YI (ASTM E313/ASTM D1925),
ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE), CIE00

Data memory

1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the “defined in COND.” mode.
* Total of the sample data and color difference target data

Pass/Fail judgment

Tolerance for color difference
(Both box and elliptical tolerances can be set)

Power source

4 AA-size batteries or AC adapter

Size (W x H x D)

69 x 96 x 193 mm

Weight

Approx. 670 g (without batteries)

Operating temperature/humidity range

5

°

C to 40

°

C, relative humidity 80% or less (at 35

°

C)

(*1)

with no condensation

Storage temperature/humidity range

0

°

C to 45

°

C, relative humidity 80% or less (at 35

°

C)

with no condensation

In combination with the optional Color Data Software
SpectraMagic™

NX

, the CM-2500c becomes a complete

Quality Control and Color Management System. The software
allows you to configure the graphic and numerical layout
according to your needs, from ultra-simple Pass/Fail
assessments to more sophisticated analysis with spectral,
color and trend graphs. The unique Navigation function of
SpectraMagic™

NX

is another useful feature to assure fast

and easy use. To improve color communication with your
customers and suppliers, SpectraMagic™

NX

allows you to

insert digital pictures in printed reports–another unique feature.

System Diagram

Standard Accessories

Optional Accessories

AA-size
batteries (x4)

AC Adapter

AC-A17

AC Adapter

AC-A23

(for Korea)

Replacement clear cover(polyolefin)
Dust Cover

CM-A152

RS-232C Cable

IF-A16

SpectraMagic™

NX

CM-S100w

Hard Case

CM-A148

Dust Cover Set

CM-A149

Zero Calibration Box

CM-A32

White Calibration Plate

CM-A153

Personal Computer

(commercially available)

Specifications

SpectraMagic™

NX

(optional)

Certificate No : JQA-E-80027

Registration Date : March 12, 1997

Certificate No : YKA 0937154

Registration Date : March 3, 1995

CM-2500c

A breakthrough in 45/0 optics with
unprecedented accuracy & stability

SPECTROPHOTOMETER

Mac OS 10.3.7J illustrator 10J

CM-2500c(E)FRONT.ai

2006.11.17

AG

MC

PK

Printed in Japan

9242-4879-51

©

2004 KONICA MINOLTA SENSING, INC.

4

SAFETY PRECAUTIONS

For correct use and for your safety, be sure to read the instruction
manual before using the instrument.

Always connect the instrument to the specified
power supply voltage. Improper connection
may cause a fire or electric shock.
Be sure to use the specified batteries. Using
improper batteries may cause a fire or electric
shock.

*1 Operating temperature/humidity range of products for North America : 5 to 40

°

C, relative humidity 80% or less (at 31

°

C) with no condensation

• Specifications are subject to change without notice.

Reviews: