Structure
The internal structure of DRYPRO 793 is shown below.
Film is transported in sequence from (1) through (7) during the printing process.
1) Pickup Unit (incorporated in each tray)
Picks up films in the pickup unit one by one and feeds them to the descent transport
unit.
2) Descent Transport Unit
Feeds films picked up from the supply unit to the justification unit.
3) Justification Unit
Aligns the right and left edges of the film received from the descent transport unit
and feeds it to the exposure unit.
4) Exposure Unit (a: Sub-scan unit, b: Main scan unit)
Performs laser scanning in synchronization with film transport and prints an image
on the film.
5) Elevator Transport Unit
Feeds the film to the HPRO (heat processing) unit after exposure.
6) HPRO Unit
Heat-processes the exposed film.
7) Cooling/Discharge Unit
Cools and discharges heat-processed film.
8) Deodorant Filter
Removes odours generated during heat processing. The deodorant filter be
changed regularly.
9) Electrical Components Unit
Consists of the power pickup unit that supplies power to the device and the control
unit for that controls the entire device, communication with diagnostic devices and
image processing/control.
10) Operation Panel
Used to operate of and make settings for DRYPRO 793.
11)Lis-793 (Option)
Ejects the film discharged from the main body to the specified bin number.
Film Pass
1) Pickup Unit
2) Descent Transport
Unit
4) Exposure Unit
5) Elevator Transport
Unit
6) HPRO Unit
7) Cooling/Discharge
Unit
8) Deodorant Filter
9) Electrical Components Unit (rear)
10) Operation Panel
3) Justification Unit
11) Lis-793