FS-601 Field Service Ver2.0 Sep. 2004
Trouble code
4-21
IV
T
rou
b
lsh
oot
in
g
2.3.11
C0B79:Punch Sensor malfunctions
A. Detection timing
B. Action
(1) Side Registration Sensor
(2) Wastes Full Sensor
Malfunction code
Description
C0B79
The light receiving voltage is 2.5 V or less when the illuminating voltage is set to
4.4 V.
The light receiving voltage is 2.5 V or more when the illuminating voltage is set to 0
V.
The illuminating voltage setting is 4.4 V or more after the adjustment has been
made.
Relevant electrical parts
Side Registration Home Sensor (PI2P-PK)
Punch Control Board (PWB-B PK)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the sensor connectors for proper
connection, and correct as necessary.
-
-
2
PI2P-PK I/O, sensor check
PWB-B PK J1006 PK-3
C-2
3
PWB-B PK replacement
-
C-1
Relevant electrical parts
Punch Control Board (PWB-B PK)
Punch Trash Full Photo Sensor Board (PWB-E PK)
Punch Trash Full LED Board (PWB-F PK)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the connection condition between
PWB-B PK and PWB-E PK.
-
-
2
Check the connection condition between
PWB-B PK and PWB-F PK.
-
-
3
PWB-E PK replacement
-
A-3
4
PWB-F PK replacement
-
A-3
5
PWB-B PK replacement
-
C-1
Summary of Contents for FS-601
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Page 38: ......
Page 40: ......
Page 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Page 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Page 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...