Mechanical operations
FS-601 Theory of Operation Ver2.0 Sep. 2004
2-10
II Co
mp
o
sit
io
n
/O
p
erat
io
n
4.2.6
Aligning mechanism
• Two Aligning Plates are moved by drive of the Front, or Rear Aligning Motor in the for-
ward or reverse direction.
• The Aligning Plates home position is detected with the Front, or Rear Aligning Plate
Home Position Sensor. With reference to this home position, the amount of movement of
the Aligning Plate is determined.
Front Aligning Motor
(M4-FN)
Front Aligning Plate
Front Aligning Plate Home Position Sensor (PI4-FN)
Shield Plate
Rear Aligning Motor
(M5-FN)
Rear Aligning Plate
Home Position Sensor
(PI5-FN)
Rear Aligning Plate
Shield Plate
Paper
(Front Side)
Summary of Contents for FS-601