Mechanical operations
FS-601 Theory of Operation Ver2.0 Sep. 2004
2-14
II Co
mp
o
sit
io
n
/O
p
erat
io
n
4.3.2
Stapling unit moving mechanism
• When the Power Switch is turned ON, or the Front Door is opened and closed, the Sta-
pling Unit is moved to the front side with the forward rotation of the Slide Motor and
stopped at the position where the Slide Home Position Sensor located at the bottom of
the Staple Unit is blocked by the Light Shield Plate.
• The Stapling Unit is moved to the rear side with the backward rotation of the Slide Motor
and stopped at its standby position.
• This standby position is determined by the number of pulses input to the Slide Motor
since it is a stepping type motor.
Stapling Unit
Shield Plate
Slide Home Position Sensor (FI18-FN)
Slide Motor
(M8-FN)