Trouble code
FS-601 Field Service Ver2.0 Sep. 2004
4-10
IV
T
rou
b
lsh
oot
in
g
2.3.2
C0B05:Paddle Motor malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B05
The Paddle Home Position Sensor (PI2-FN) is not unblocked even after the lapse
of a given period of time after the Paddle has started moving from its home posi-
tion.
The Paddle Home Position Sensor (PI2-FN) is not blocked even after the lapse of a
given period of time after the Paddle has started moving from a position not the
home position.
The Swing Guide Home Position Sensor (PI3-FN) is not unblocked even after the
lapse of a given period of time after the Booklet Roller has started moving from its
home position.
The Swing Guide Home Position Sensor (PI3-FN) is not blocked even after the
lapse of a given period of time after the Booklet Roller has started moving from a
position not the home position.
Relevant electrical parts
Paddle Home Position Sensor (PI2-FN)
Swing Guide Home Position Sensor (PI3-FN)
Paddle Motor (M2-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PI2-FN I/O, sensor check
PWB-A FN CN9 FN-2
H-5
4
PI3-FN I/O, sensor check
PWB-A FN CN9 FN-8
I-5
5
M2-FN operation check when the Power
Switch is turned OFF and ON.
-
A-9
6
PWB-A FN replacement
-
E-6
Summary of Contents for FS-601
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Page 38: ......
Page 40: ......
Page 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Page 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Page 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...