Trouble code
FS-601 Field Service Ver2.0 Sep. 2004
4-12
IV
T
rou
b
lsh
oot
in
g
2.3.4
C0B39:Front Aligning Plate Motor malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B39
The Front Aligning Plate Home Position Sensor (PI4-FN) is not unblocked even
after the lapse of a given period of time after the Front Aligning Plate has started
moving from its home position to a position out of the home position.
The Front Aligning Plate Home Position Sensor (PI4-FN) is not blocked even after
the lapse of a given period of time after the Front Aligning Plate has started moving
from a position out of the home position to the home position.
Relevant electrical parts
Front Aligning Plate Home Position Sensor (PI4-
FN)
Front Aligning Motor (M4-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PI4-FN I/O, sensor check
PWB-A FN CN4 FN-2
E-8
4
M4-FN operation check when the Power
Switch is turned OFF and ON.
-
B-7
5
PWB-A FN replacement
-
E-6
Summary of Contents for FS-601
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Page 38: ......
Page 40: ......
Page 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Page 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Page 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...