FS-601 Field Service Ver2.0 Sep. 2004
Trouble code
4-19
IV
T
rou
b
lsh
oot
in
g
2.3.9
C0B76:Punch Side Registration Motor malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B76
The Side Registration Home Sensor (PI2P-PK) is not unblocked even after the
lapse of a given period of time after the Punch Side Registration Unit has started
moving from its home position.
The Side Registration Home Sensor (PI2P-PK) is not blocked even after the lapse
of a given period of time after the Punch Side Registration Unit has started moving
from a position not the home position.
Relevant electrical parts
Side Registration Home Sensor (PI2P-PK)
Punch Control Board (PWB-B PK)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the sensor connectors for proper
connection, and correct as necessary.
-
-
2
PI2P-PK I/O, sensor check
PWB-B PK J1006 PK-3
C-2
3
PWB-B PK replacement
-
C-1