FS-601 Field Service Ver2.0 Sep. 2004
Trouble code
4-23
IV
T
rou
b
lsh
oot
in
g
2.3.13
C0BF1:Backup RAM malfunction
A. Detection timing
B. Action
Malfunction code
Description
C0BF1
Data written in the Backup Memory differs from what is recorded in it and writing
operation is not correctly performed even with two retry sequences (a total of three
writing sequences).
Relevant electrical parts
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Disconnect and then connect the power
cord to turn OFF and ON the main
switch.
-
-
2
Check the connectors for proper connec-
tion on the PWB-A FN.
-
-
3
PWB-A FN replacement
-
E-6