C0B25:Stapler Unit Slide Motor malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B25
The Slide Home Position Sensor (PI18-FN) is not unblocked even after the lapse of
a given period of time after the Stapler Unit has started moving from its home posi-
tion.
The Slide Home Position Sensor (PI18-FN) is not blocked even after the lapse of a
given period of time after the Stapler Unit has started moving from a position not
the home position.
Relevant electrical parts
Slide Home Position Sensor (PI18-FN)
Slide Motor (M8-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PI18-FN I/O, sensor check
PWB-A FN CN11 FN-3
F-2
4
M8-FN operation check when the Power
Switch is turned OFF and ON.
-
I-8
5
PWB-A FN replacement
-
E-6
Summary of Contents for FS-601
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Page 38: ......
Page 40: ......
Page 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Page 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Page 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...