13
(2) Irrigate salt water
Take 500g salt and 1000g water to mix
and then pour the salt water to the
iron bar.
(3) Wiring
Get a wire more than 2 flat, weld the
wire to the iron bar with electric welding
torch (uneasy to fall off) .Please
connect the other end of ground signs
on the machine screws at the nail. If
you do not find the mark on the
machine, connect to the exposed parts
of the machine (the parts without
painting, such as castor and public
wiring board ground)
(4)Measurement of ground resistance
When the machine power on, measure
the machine phase and the zero line
with
electric
pen
(methods
of
measurement refer to relative literature)
Then turn off the machine, make the
Multimeter to the smallest gear
resistance, measure the resistance
between the ground and the zero line,
resistance should be less than 10 ohms
Notice
!
The
salt must dissolve into
water completely.
Pour the iron bar with salt
water once a month to
guarantee
the
iron
conductivity.