17. Fusing section
Theory of operation ver. 1.0 July. 2006
62
magicolor 2490MF
Composition/Operation
17.3.2
Fusing temperature control
• A thermistor is used to detect the surface temperature of the heating roller. The heater
lamp is then turned ON and OFF as necessary to achieve the set temperature.
Temperature control during monochrome printing (plain paper)
[1] During warm-up
Heat the heating roller temperature to
178
°
C in average 45 seconds.
(100 V – 120 V area)
Heat the heating roller temperature to
178
°
C in average 49 seconds.
(220 V – 240 V area)
[3] During a print cycle
Heating roller temperature setting: 169
°
C
*b: If the temperature/humidity sensor detects
a temperature of less than
20
°
C, temperature control is performed with
the heating roller temperature setting
changed to 174
°
C.
[2] In standby state
Heating roller temperature setting: 180
°
C
*a: If the heating roller temperature is 60
°
C or
less when the warm-up cycle is started, tem-
perature control is performed with the heating
roller temperature setting changed to 185
°
C.
(5 min.)
After the lapse of the 5 min. period, the tem-
perature stabilizes at 180
°
C.
[4] In standby state
heating roller temperature setting: 180
°
C
100
60
Approx. 45 sec.
169
167
180
185
174
㧔͠㧕
Power Switch ON
Fusing Ready Temperature
Copy/Print Start
[3]
[4]
[2]
[*a]
[1]
4139T2E563AA
[*b]
Warm-up completed (approx.70 seconds for 100 V area)
(approx.75 seconds for 200 V area)
Summary of Contents for Magicolor 2490 MF
Page 1: ...SERVICE MANUAL 2006 07 2006 07 Ver 1 0 Ver 1 0 magicolor 2490MF THEORY OF OPERATION ...
Page 3: ...ii ...
Page 108: ...SERVICE MANUAL 2006 07 Ver 1 0 Auto Document Feeder Unit THEORY OF OPERATION ...
Page 122: ...SERVICE MANUAL 2006 07 Ver 1 0 Lower Feeder Unit THEORY OF OPERATION ...
Page 134: ...SERVICE MANUAL 2006 07 Ver 1 0 Duplex Option THEORY OF OPERATION ...