Field Service Ver. 1.0 May 2006
2. Periodical check
3
L
o
w
er
F
eeder
U
n
i
t
Maintenance
Maintenance
2.
Periodical check
2.1
Maintenance procedure (Periodical check parts)
2.1.1
Replacing the Separation Roller
1.
Slide out the Tray.
2.
Open the Vertical transport door.
3.
Remove two Claws [1], and remove
the Vertical transport door [2].
4.
Remove two Screws [3], and remove
the Jam processing cover [4].
NOTE
• Make sure the position of the Mylar
when installing the Jam processing
cover.
[1]
[2]
4039F2C048DA
[3]
[3]
[4]
OK
NG
4039F2C049DA