Field Service Ver. 1.0 May 2006
5. Firmware upgrade
33
magicolor 7450
Maintenance
5.
Copy the firmware data and upgrading program to any directory on the PC.
6.
Start the Command Prompt and go to the directory in which the firmware data is
stored.
7.
Execute the following command to start the transfer of the firmware data to the printer.
(The screen shown below indicates that the firmware data resides on the C drive.)
8.
Wait until all of the data is sent. (This takes approximately 2 minutes.)
While the data is being sent, [FIRMWARE UPDATE] and [RECEIVING DATA] are alter-
nately displayed on the screen.
NOTE
• Never turn the printer power switch OFF and ON while data is being sent.
9.
After the data has finished being sent, the following message appears on the screen of
the Command Prompt.
Data to be upgraded
Command
FW upgraded data
> copy /b 4039**********.prn prn
******: File name of FW upgrade data
4039F2E522DA
㪋㪇㪊㪐
㪋㪇㪊㪐
4138F2C009DA
FIRMWARE UPDATE
RECEVING DATA
4039F2E523DA
㪋㪇㪊㪐
Summary of Contents for magicolor 7450
Page 1: ...SERVICE MANUAL 2006 05 2006 05 Ver 1 0 Ver 1 0 FIELD SERVICE magicolor 7450 magicolor 7450 ...
Page 3: ...ii Blank Page ...
Page 26: ...SERVICE MANUAL 2006 05 Ver 1 0 FIELD SERVICE Main Unit magicolor 7450 magicolor 7450 ...
Page 43: ...2 Product specifications Field Service Ver 1 0 May 2006 6 magicolor 7450 General Blank Page ...
Page 288: ...SERVICE MANUAL 2006 05 Ver 1 0 FIELD SERVICE Lower Feeder Unit ...
Page 317: ...3 Other Field Service Ver 1 0 May 2006 26 Lower Feeder Unit Maintenance Blank Page ...
Page 328: ...SERVICE MANUAL 2006 05 Ver 1 0 FIELD SERVICE Duplex Option ...
Page 333: ...1 Product specifications Field Service Ver 1 0 May 2006 2 Duplex Option General Blank Page ...
Page 345: ...6 Jam Display Field Service Ver 1 0 May 2006 14 Duplex Option Troubleshooting Blank Page ...