USER INSTRUCTIONS / FUNCTION
TECHNICAL DATA
Material
Tubes, sheet metal parts, screws:
- steel, powdered, black
Screws, washers, threads:
- steel, galvanized
Bushings, caps, handles, holders:
- PA, PE, POM, black
Bracket covers, parquet protectors:
- TPE, black
Dimensions
Footprint: W x D 400 x 440 mm
Height: 650 - 920 mm
Weight
3.1 kg
Box
inside: 675 x 400 x 130 mm
Carrying case
K&M 11450
4. ADJUSTMENT OPTIONS
5. HANG UP THE INSTRUMENT
6. DIMENSIONS
4. ADJUSTMENT OPTIONS
- Always change settings in the unloaded state.
4.1 POSITION - BOTTOM BRACKET
4.1
Grasp the support bracket
c
by the retaining
4.1
clip
c.1
and move it to the desired position.
4.1
The pretension of the clamp holds the support
4.1
bracket is securely in the selected position.
4.2 POSITION - MOUNTING BRACKET TOP
4.2.1
Slightly loosen the spring-loaded clamping knob
4.2.2
Pull the handle until the bolt disengages
4.2.3
Retracting or extending the extension tube
4.2.4
Engage bolt and tighten handle
4.3 SHAPE & SIZE OF BOTH BRACKETS
4.3
Inside the rubber-like plastic (TPE) coated
4.3
stirrups are steel bands which can be bent
4.3
open or closed a little bit.
4.3
If necessary, the respective bracket can be
4.3
adjusted to the size of the bell by powerful
4.3
yet gentle bending.
5. HANG UP THE INSTRUMENT
5.1 CHECKING THE SETTING
5.1
Before use, ensure that the extension tube
5.1
is extended far enough to prevent the
5.1
instrument from touching the floor
5.2 HANG UP THE INSTRUMENT
5.2.1
Hook the bell close to the edge into the
5.2.1
mounting bracket at the top, so that the
5.2.1
instrument cannot slip down
5.2.2
Place the instrument on the bottom of
5.2.2
the mounting bracket
5.2.3
The baritone saxophone rests in the
5.2.3
two brackets
5.3 NOTE
5.3
Danger of slipping due to careless mounting.
5.3
Especially a distance between bell and mounting
5.3
bracket could cause the instrument to slip. This
5.3
must be avoided at all costs.
6. DIMENSIONS
MAINTAIN, CLEAN
- Always carry out maintenance in unloaded condition
- Regularly check:
-
a. proper condition of the components (defective
-
a.
parts must be replaced or repaired)
-
b. Tight fit of all screw connections
- Pay attention to possible hazards during
-
maintenance work like bumping, overturning,
-
squeezing
- It is best to use a slightly damp cloth for
-
cleaning and use non-abrasive cleaning agent
FAULT-FINDING (F) and REPAIR (R)
F: Stand wobbles
F:
B: Check the substrate or put it in order
F:
B: Adjust the adjustable end cap
F:
B: Make sure that both foot tubes are
F:
B:
extended to the stop
B: Tighten the screw connection of the rear support
F: Instrument wobbles
F:
B: Bending the mounting bracket
F:
B: Optimise the position of the lower support bracket
KÖNIG & MEYER
GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
14415-000-55 Rev.05 03-80-648-00 8/20
Slightly loosen
the spring-loaded
clamping knob
Pull the
handle until the
bolt disengages
Retracting
or extending the
extension tube
Engage bolt and
tighten handle