background image

KÖNIG & MEYER

 GmbH & Co. KG  

Kiesweg 2, 97877 Wertheim, www.k-m.de 
Rev.01  03-80-911-00  10/19

Cause/increase 

of lateral forces

Remedy 

(how they are switched off or minimized)

- Sloping and unstable surface

 

Use only level and stable surface

- Excentric loads

 

If possible, place the load centrically,  

 

otherwise reduce it accordingly

- Air in the plug connection between tube and base

 

Use of the K&M 85890 levelling adapter  

 

or K&M »Ring Lock« systems

- Unfavourable relationship between base and load

 

Generally:  lower centre of gravity, i.e.  

 

ensure appropriate conditions - anchor base  

 

if necessary or weigh it down

- External influences (wind, pushes, etc.)

 

provide for protection or distance

Safety data sheet for 
K&M Distance rods 

These safety instructions are valid for the following articles: 

 
Plug-in tubes:   21333, 21336, 21338, 21348, 21356 
Screw tubes:    21329, 21334, 21337, 21339, 21340, 21347, 21357, 21364, 21367, 21368, 26736 
»Ring Lock«:    21360, 21366

 

APPLICATION

The following components generally belong to the installation of a distance rod: 

 

1. Base (base plate or subwoofer) 
2. Distance rod 
3. Load (satellite or similar) 

 

Distance rods do not operate on their own, but only together with a base (base plate or subwoofer).

SAFETY INSTRUCTIONS

The installation must be adequately protected against the risk of tipping. This is considered to be the case if it meets the 
test criteria of the standard specification (DIN56950-3). There it says: 

 

The installation is:  a. inclined by 5°, 

                              b. fully extended, 
                              c. positioned in the most unfavourable position (alignment of the base, load distribution etc.) 

 

In fact, this test setup simulates whether the installation offers sufficient resistance to possible lateral forces.

It also depends on the quality and design of the connection between base and distance rod: 

 

- The quality of the sockets and loudspeaker cabinets must be given. Particularly, the effect of lateral forces strains the  

-

 sockets and boxes. 

- Depending on the size of the loudspeaker sockets, the plugged distance rods make more or less "air" available to  

-

 warrant the mobility of the connection. This allows the tube and satellite to sit at different angles on the subwoofer. 

- Distance rods with »Ring Lock« system initially function like plug-in tubes; only the tightening of the locking ring(s)  

-

 results backlash-free fitting of the tube. 

- Distance rods with M20 screw connections must always be firmly screwed on up to the stop (see picture screw  

-

 connection). 

Summary of Contents for 21356

Page 1: ...rstutzen und der b Lautsprecherbuchse welches je nach Fabrikat leicht b unterschiedlich ausfallen kann Ein gewisses Spiel muss sein b um eine dauerhafte Gängigkeit zu gewährleisten Ggf den b Adapterring 85890 einsetzen siehe 3 c SICHERHEIT WÄHREND DES BETRIEBES c Stange zentrisch belasten c außermittige Lasten beeinträchtigen die Standfestigkeit c Unbefugte von der Installation fern halten c Siche...

Page 2: ...steckhilfe die das Aufsetzen des Lautsprechers wesentlich erleichtert Beteiligte EP Erste Person bedient das Auszugrohr mit der Last ZP Zweite Person bedient Klemmschraube und Rastbolzen der Spannschelle Reihenfolge beim Ausfahren EP 1 hält Auszugrohr fest ZP 2 lockert Klemmschraube und hält diese fest ZP 3 zieht den Rastknopf bis sich der Rastbolzen ZP 3 nicht mehr im Eingriff befindet EP 4 führt...

Page 3: ... manufacturer can differ somewhat A little play is required to b ensure continued usability If needed use Adapter Ring b 85890 refer to 3 c SAFETY DURING OPERATION c Be sure the weight on the rod is centered if the weight is not c centered this has a negative affect on stability c Keep unauthorized individuals away from the installation c Ensure that the clamp screw 7 is tight and the locking pin ...

Page 4: ...o called placement help which makes it much easier to place the loudspeaker onto the rod Technicians FP First Person operates the distance rod with the box SP Second Person operates the clamping bracket s clamping screw and locking pin Sequence when extending the rod FP 1 holds the distance rod SP 2 loosens the clamp screw and holds it SP 3 pulls the locking knob until the locking pin SP 3 is no l...

Page 5: ...itschaft nicht aus sich selbst heraus sondern nur zusammen mit einer Basis Bodenplatte oder Subwoofer herstellen SICHERHEITSHINWEISE Die Installation muss ausreichend gegen die Gefahr des Kippens gewappnet sein Dies gilt als gegeben wenn die sie den Prüfkriterien der Stativnorm DIN56950 3 standhält Dort heißt es Die Installation ist a um 5 geneigt b vollständig ausgezogen c in ungünstigster Stellu...

Page 6: ...iesem Fall sind es max 35 kg B Die Standsicherheit Tragkraft wie viel kg kann es unter den örtlichen B Gegebenheiten tragen bevor es kippt kg Bestehen des 5 Kipptestes vor Ort B Achtung Die Sicherheit des Tests gewährleisten Der geringere der beiden Werte gilt Dieser entspricht fast immer der im 5 Kipptest festgestellten Maximallast jedoch nicht mehr als max 35 kg GEFAHRENZONE Das Distanzrohr kann...

Page 7: ...do not operate on their own but only together with a base base plate or subwoofer SAFETY INSTRUCTIONS The installation must be adequately protected against the risk of tipping This is considered to be the case if it meets the test criteria of the standard specification DIN56950 3 There it says The installation is a inclined by 5 b fully extended c positioned in the most unfavourable position align...

Page 8: ...y load bearing capacity how many kg can it carry under local conditions B before it tilts kg passing the 5 tilting test on site B Attention Ensure the safety of the test The lower of the two values applies This almost always corresponds to the maximum load determined in the 5 tipping test but not more than max 35 kg DANGER ZONE The distance tube can act like a big lever a Lateral forces can put a ...