background image

26747
Beamer Tray

- secure and stable thanks to welded tray supports
- suitable for loud speakers, lighting, screen/monitor stands etc. with tube diameter of 35 mm.
- includes 4 rubber knobs - self-adhesive, any position  
- load bearing weight: max. 35 kg
- tray 384 x 424 mm, Weight 3.1 kg

SAFETY NOTES

SET UP INSTRUCTIONS

KÖNIG & MEYER

GmbH & Co. KG 

Kiesweg 2, 97877 Wertheim, www.k-m.de

26747-000-55  Rev.01  03-80-238-00  2/13

1

Place four rubber knobs in accordance with the size of 

1

the beamer; these are self-adhesive, i.e. first remove 

1

the protective foil and place the knobs in the desired 

1

spots

2

Untighten the screw until the thread is no longer inside 

2

the supporting tube

3

Place the tray with the tubing supports on the  

3

extension tube

4

Tighten the screw until the beamer tray is tightly affixed 

4

to the extension tube

4

ENSURE that the screws are not too tight so that the 

4

components are not negatively affected, all that is 

4

needed is that the screws are tightened by hand.

5

Place the beamer on the middle of the tray, pay 

5

attention to the rubber knobs

6

Adjust the extension tube height of the stand and 

6

secure (e.g. rest bolts or tracks - depending on the 

6

stand) 

7

a. To adjust the direction the beamer loosen the screw 

7

a.

somewhat, 

7

b. Set the tray and retighten the screw

Disassembly is performed in reverse order

- max. central load: 35 kg
- only use suitable stands: e.g K&M stands with 

-

ø 35 mm: 213, 21302, 21435, 21436, 21440, 21455, 

-

21460, 26750 

- remove beamer from the tray prior to moving the stand.
- the floor must be load bearing and even.
- use of personnel for set up as required.
- keep unauthorized personnel away from the stand. 
- maintain safety when installing and assembling the 

-

system.

Materials

Tube supports with tray: Steel, black powder coating

Load

max. 35 kg central load,
however no more than the load borne by the stand

Dimensions

Tray: 384 x 424 x 8,5 x 2 mm, Tube support: I.ø 3 6 x 100 mm

Packaging

PE-Bag: 610 x 630 mm

TECHNICAL DATA

CONTROL, MAINTENANCE, CLEANING

- Perform workstation maintenance only without the beamer on the 

-

tray and watch for eventually risks (wedged in, bumped, the beamer 

-

falls over)

- To care for the product use a damp cloth and a non-abrasive 

-

cleaning agent.

FAULT FINDING (F) and REPAIR (R)
F: Stand or extension arm wobbles.  

F: 

R: Ensure floor is even, check stand, re-tighten screws

F: The tray wobbles and turns.   

F: 

R: Tighten the clamp screw.

Thank you for choosing this product. This instruction manual informs you about
the important steps to set up an handle the product. We recommend to keep the
manual in a separate place for a possible later use.