background image

CHECK, MAINTENANCE, CLEANING

- Careful use of the stand maintains the use of the telescope and the load 

-

bearing functionality of the stand as well as the safety of the installation

- Perform workstation maintenance only without the monitor and watch for 

-

eventually risks (wedged of hands, bumping into stand, the stand may fall over)

- To care for the product, use a damp cloth and and a non-abrasive cleaning 

-

agent.

TECHNICAL DATA

FAULT-FINDING (F) and REPAIR (R)

Material

Base, tube, catch, joint, tray: Steel, black powder coated
Threads: Steel, galvanized
Bracket, shell, caps: PA-6

Load

max 35 kg centered load

Dimensions

Base: Root diameter 600 mm, t= 6 mm
Tube combination: ø 42 / ø 35 mm
Height: min. 800 - max. 1300 mm (10 x 50 mm)
Tray: W x D 230 x 250 mm
Angle: level +/-12,5°

Box

L x W x H:  810 x 540 x 170 mm

Weight

net.: 6.8 kg, gross: 9.8 kg

F: The stand is not sturdy i.e. is leaning to one side:

F:

R: Check if the surface is even 

F:

R: Check if the base is level

F:

R: Check and, if needed, tighten the screws 

f

F: R:

on the base 

a

and base tube 

b.1

F: The extension tube 

b.3

retracts on its own:        

F:

R: Press the catch into the groove and tighten the wing nut (

4.3-4.5

)

F: The monitor tray 

c

tilts on its own: 

F:

R: Tighten the screws on the joint (

8.4

)

F: Monitor slips: 

F:

R: The safety ledge must be at the bottom 

9

, if needed disassemble 

F: R:

and reassemble so that it is on the bottom.

13 DIMENSIONS

Summary of Contents for 26754

Page 1: ...die Muttern 8 4 nachgezogen werden C Rohrkombination stets so zentrisch wie m glich belasten 12 da au ermittige C Belastung die Standfestigkeit der Installation beeintr chtigt D VOR DEM BETRIEB D Vor...

Page 2: ...ie end Auszugrohr einfahren lassen und 5 4 Fanghaken wieder in die vorgesehene ffnung 5 4 dr cken und in das Rohr einhaken lassen 5 5 Fl gelmutter wieder festziehen MONITOR AUFLAGE PLATTE 6 12 6 GUMMI...

Page 3: ...latte beide 11 1 Verschraubungen ENTFERNEN 11 1 Zun chst Kappen abziehen 11 1 anschlie end Sicherungsmuttern 11 1 und U Scheiben entfernen 11 1 Dazu Schl ssel SW10 i benutzen 11 2 Ablageplatte c abheb...

Page 4: ...5 kg zentrische Last Abmessungen Sockel Fu kreis 600 mm t 6 mm Rohrkombination 42 35 mm H he min 800 max 1300 mm 10 x 50 mm Ablageplatte B x T 230 x 250 mm Neigbarkeit waagerecht 12 5 Karton L x B x H...

Page 5: ...tray and held securely C If the tray tilts the nuts 8 4 have to be tightened C The load is to be centered on the tube combination 12 anything C that is not centered can have a negative effect on stan...

Page 6: ...locks automatically 5 3 Then let the extension tube retract and 5 4 press the catch into the desired 5 4 groove until it clicks into place 5 5 Re tighten the wing nut MONITOR TRAY 6 12 6 RUBBER PROTEC...

Page 7: ...d 11 1 underneath the tray 11 1 First take off the caps 11 1 then remove the safety nuts 11 1 and washers 11 1 To accomplish this use SW10 i Allen wrench hexagon key 11 2 Remove tray c 11 3 turn it 18...

Page 8: ...35 kg centered load Dimensions Base Root diameter 600 mm t 6 mm Tube combination 42 35 mm Height min 800 max 1300 mm 10 x 50 mm Tray W x D 230 x 250 mm Angle level 12 5 Box L x W x H 810 x 540 x 170 m...