background image

KÖNIG & MEYER

 GmbH & Co. KG  

Kiesweg 2, 97877 Wertheim, www.k-m.de 
Rev.01  03-80-911-00  10/19

Cause/increase 

of lateral forces

Remedy 

(how they are switched off or minimized)

- Sloping and unstable surface

 

Use only level and stable surface

- Excentric loads

 

If possible, place the load centrically,  

 

otherwise reduce it accordingly

- Air in the plug connection between tube and base

 

Use of the K&M 85890 levelling adapter  

 

or K&M »Ring Lock« systems

- Unfavourable relationship between base and load

 

Generally:  lower centre of gravity, i.e.  

 

ensure appropriate conditions - anchor base  

 

if necessary or weigh it down

- External influences (wind, pushes, etc.)

 

provide for protection or distance

Safety data sheet for 
K&M Distance rods 

These safety instructions are valid for the following articles: 

 
Plug-in tubes:   21333, 21336, 21338, 21348, 21356 
Screw tubes:    21329, 21334, 21337, 21339, 21340, 21347, 21357, 21364, 21367, 21368, 26736 
»Ring Lock«:    21360, 21366

 

APPLICATION

The following components generally belong to the installation of a distance rod: 

 

1. Base (base plate or subwoofer) 
2. Distance rod 
3. Load (satellite or similar) 

 

Distance rods do not operate on their own, but only together with a base (base plate or subwoofer).

SAFETY INSTRUCTIONS

The installation must be adequately protected against the risk of tipping. This is considered to be the case if it meets the 
test criteria of the standard specification (DIN56950-3). There it says: 

 

The installation is:  a. inclined by 5°, 

                              b. fully extended, 
                              c. positioned in the most unfavourable position (alignment of the base, load distribution etc.) 

 

In fact, this test setup simulates whether the installation offers sufficient resistance to possible lateral forces.

It also depends on the quality and design of the connection between base and distance rod: 

 

- The quality of the sockets and loudspeaker cabinets must be given. Particularly, the effect of lateral forces strains the  

-

 sockets and boxes. 

- Depending on the size of the loudspeaker sockets, the plugged distance rods make more or less "air" available to  

-

 warrant the mobility of the connection. This allows the tube and satellite to sit at different angles on the subwoofer. 

- Distance rods with »Ring Lock« system initially function like plug-in tubes; only the tightening of the locking ring(s)  

-

 results backlash-free fitting of the tube. 

- Distance rods with M20 screw connections must always be firmly screwed on up to the stop (see picture screw  

-

 connection). 

Summary of Contents for Ring Lock

Page 1: ...NUTZERHINWEISE Richtung des Lautsprechers verändern Sicherungsring nach rechts drehen Richtung OPEN Satellitenbox in gewünschte Position bringen Sicherungsring nun nach links drehen Richtung CLOSE Abmessungen s Abb 1 TECHNISCHE DATEN SPEZIFIKATIONEN Material Rohr Stahl pulverbeschichtet Farbe schwarz Schrauben Stahl verzinkt Sicherungsringe Alu Spreizelemente PA Traglast max 35 kg Abmessungen H 75...

Page 2: ...e speakers Turn the ring lock to the right direction OPEN Place satellite speaker in the desired position Now turn the ring lock left direction CLOSE Dimensions refer to illustration 1 TECHNICALINFORMATION SPECIFICATIONS Material tubes steel powder coated color black screws steel galvanized ring lock aluminum mandrel elements PA Load max 35 kg Dimensions H 750 mm expanding mandrel system ø 35 37 x...

Page 3: ...itschaft nicht aus sich selbst heraus sondern nur zusammen mit einer Basis Bodenplatte oder Subwoofer herstellen SICHERHEITSHINWEISE Die Installation muss ausreichend gegen die Gefahr des Kippens gewappnet sein Dies gilt als gegeben wenn die sie den Prüfkriterien der Stativnorm DIN56950 3 standhält Dort heißt es Die Installation ist a um 5 geneigt b vollständig ausgezogen c in ungünstigster Stellu...

Page 4: ...iesem Fall sind es max 35 kg B Die Standsicherheit Tragkraft wie viel kg kann es unter den örtlichen B Gegebenheiten tragen bevor es kippt kg Bestehen des 5 Kipptestes vor Ort B Achtung Die Sicherheit des Tests gewährleisten Der geringere der beiden Werte gilt Dieser entspricht fast immer der im 5 Kipptest festgestellten Maximallast jedoch nicht mehr als max 35 kg GEFAHRENZONE Das Distanzrohr kann...

Page 5: ...do not operate on their own but only together with a base base plate or subwoofer SAFETY INSTRUCTIONS The installation must be adequately protected against the risk of tipping This is considered to be the case if it meets the test criteria of the standard specification DIN56950 3 There it says The installation is a inclined by 5 b fully extended c positioned in the most unfavourable position align...

Page 6: ...y load bearing capacity how many kg can it carry under local conditions B before it tilts kg passing the 5 tilting test on site B Attention Ensure the safety of the test The lower of the two values applies This almost always corresponds to the maximum load determined in the 5 tipping test but not more than max 35 kg DANGER ZONE The distance tube can act like a big lever a Lateral forces can put a ...