background image

 

KONLEN TECHNOLOGY LIMITED

 

Website: www.konlen.com

 

U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China 

Tel: +86-(0)755-86082432 E-mail: 

klalarm@konlen.com

 MSN: 

konlensales@hotmail.com

 Skype: securitykonlen 

 
 

- 3 - 

 

1.

 

Insert SIM in alarm unit. 

Press yellow point gently with a pencil tip. SIM tray will come out. 

Put the SIM in it and insert in back. 

Attention! Metal contacts of the SIM must be down. Check it to be inserted correctly in the unit. 

Before insert SIM in alarm unit, using a regular mobile phone do the following steps: 

-

 

Set PIN code request to off. 

-

 

Delete all stored numbers 

-

 

Store  only  numbers  desired  for  alarming  (up  to  5  numbers).  Numbers  must  be  inserted  in 

order of calling. First stored will be first called, second stored will be second called and so 

on. 

 
2.

 

Connect the antenna.  

Attention!  Be careful, do not over-tighten the nut or let it loose! 
 
3.

 

Connect the siren to alarm system: connect red wire to ground (public) port 
and black wire to siren port. 

 

 

Siren 

 

4.

 

How to distinguish 8 LEDs on the main panel? 

 

 

 

OUT1, OUT 2 and OUT 3:  show the status of output 1,2 and 3. They can be used to three lights 

or other home appliances. 

RELAY: The fourth LED. It shows relay status. There is a on-board relay inside. The Relay LED 

will be on when the relay’s two ports are closed. 

ALARM: The fifth LED shows the working status of siren. If siren is triggered, the “Alarm” LED 

will be on. 

MONITOR: When it is on, it means the system is in the status of listening-in. 

Summary of Contents for KL-h21a

Page 1: ... com U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 1 GSM Home Alarm System KL H21A Installation and Users guide ...

Page 2: ...lephone anytime wherever you are For security reasons a PIN code must be used for access 7 Supports all kinds of wireless sensors such as PIR detectors door gap sensors gas sensors smoke sensors panic buttons and infrared balusters are available 8 Supports any wired sensors available NC contacts 9 Supports any combination of wired wireless sensors as you need 10 No need for fixed telephone line Is...

Page 3: ...or alarming up to 5 numbers Numbers must be inserted in order of calling First stored will be first called second stored will be second called and so on 2 Connect the antenna Attention Be careful do not over tighten the nut or let it loose 3 Connect the siren to alarm system connect red wire to ground public port and black wire to siren port Siren 4 How to distinguish 8 LEDs on the main panel OUT1...

Page 4: ... The third and fourth ports inner relay input It is normally opened It will keep closed for three minutes when alarming O1 O2 andO3 output control I1 I2 and I3 inputs for wired detectors Attention Power supply delivered in the kit is an UPS 12V is present at the plug even power supply unit is not plugged in AC socket Operating the system Using of remote controller 1 Arming button press it to arm s...

Page 5: ...of alarm system for audio monitoring of the spot q 9 stop monitoring listening in and open the siren r 0 arm the system s 0 disarm the system Advanced Instructions 1 Resetting the system NOTICE Resetting the system all coded information and messages will be lost System will be loaded with basic factory settings The passwords will be back to the original default 1234 You must code register all wire...

Page 6: ...of wireless sensors that can be coded by system is 10 But you can register countless wireless sensors by changing sensors ID 3 Connecting wired sensors Three inputs are available to connect wired sensors Inputs are independent but are not coded as different zones When sent SMS it will show Wired Activated Sensors must be NC normally closed type You can connect more than 1 sensor at one input conne...

Page 7: ...omponents and optional available components Basic Kit contains Alarm system central unit 1 pc Wireless PIR detector 1 pc Wireless door gap sensor 1 pc Remote controller 2 pcs Antenna 1pc Mini wired siren 110dB 0 3m 1 pc Power supply with back up 1pc Users Manual 1pc The following sensors can be optional Additional wireless products Optional sensors detectors are packed separately It includes remot...

Page 8: ...echnical Parameters GSM Alarm Module Operating voltage DC6V Average power AC DC exchanger 2A Wireless receiving distance 100m Operating Frequency 315 or 433 92 MHZ GSM 900 1800MHZ 850MHZ is optional Operating voltage DC12V AC 220 110V Wireless receiving distance 100m 250m Outer Alarm Siren Volume 110 dB Working Condition Temperature 10 40 Humidity 90 rh Wireless Gap Detector Door Window Contact Po...

Page 9: ...nternal Distance 15 mm Working Condition Temperature 10 40 Humidity 90 rh Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current 100 mA Transmission Current 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 40 Humidity 90 ...