GPS\GSM fleet management tracking system www.konlen.com
16-18
3.3.17 Fatigue drving alarm
Fatigue driving alarm is also known as overtime driving warning. User can set an allowable time value of
countinuous driving. When the dirving time exceeds the preset premitted value, the device send fatigue
driving alarm to center immedialtely, which can control driving time and reduce the traffice accident
caused due to continous overtime fatigue driving effectively.
3.3.18 User-defined trigger alarm
Users can install the two self-defined trigger alarm wire of 103A3A according to 2.5 103A3A installation
diagram, and define the alarm content by themselves such as illegal door open, robbery alarm etc. Usually,
the user-defined alarm is combined with the function of camera photo taking. User can install the
self-defined wire with car door, SOS button and taximeter etc, and set cameras to take pictures immedialy
upon illegal door open, SOS button triggered or Taxi driver metering.
3.3.19 Emergency alarm
Please press 2 seconds on emergency button to trigger an SOS alarm for help when there is an emergency.
The terminal device immediately uploads emergency alarm to monitoring center. Please take action to deal
with the alarm quickly.
3.3.20 Main power off alarm
The terminal device will issue a power off warning in 3 seconds when the main power supply was cut off,
at the same time start the backup battery (can last around 2 to 4hours), again automatically detect whether
cancel the alarm after 30secounds. Center could confirm or cancel the alarm after alert received. The
voltage detecting value of power off alarm <DC 7V
3.3.21 Main power undervoltage alarm
The terminal device will issue undervoltage warning immediately to monitoring center while the main
power suplly is undervoltage, at same time start the backup up battery(can last around 2 to 4hours). It will
auto-check whether cancel the alarm or not 30s later. The undervoltage detecting value <DC9V.
3.3.22 GPS antenna failure alarm
The tracking device will report the GPS antenna failure alarm to monitoring center immediately when the
GPS antenna is damaged,
3.3.23 Illegal ignition warning
User can set a time range that not premitted to start engine via montoring center. If the driver start engine
within the prohibited time, the tracking device will report illegal ignition warning data to center.
Monitoring center can confirm or cancel the alarm as well as disable the function.