background image

GPS\GSM fleet management tracking system    www.konlen.com                                                                                           

16-18 

3.3.17 Fatigue drving alarm

 

Fatigue driving alarm is also known as overtime driving warning. User can set an allowable time value of 

countinuous  driving.  When  the  dirving  time  exceeds  the  preset  premitted  value,  the  device  send  fatigue 

driving  alarm  to  center  immedialtely,  which  can  control  driving  time  and  reduce  the  traffice  accident 

caused due to continous overtime fatigue driving effectively. 

 

3.3.18 User-defined trigger alarm 

Users can install the two self-defined trigger alarm wire of 103A3A according to 2.5 103A3A installation 

diagram, and define the alarm content by themselves such as illegal door open, robbery alarm etc. Usually, 

the  user-defined  alarm  is  combined  with  the  function  of  camera  photo  taking.  User  can  install  the 

self-defined wire with car door, SOS button and taximeter etc, and set cameras to take pictures immedialy 

upon illegal door open, SOS button triggered or Taxi driver metering. 

 

3.3.19 Emergency alarm 

Please press 2 seconds on emergency button to trigger an SOS alarm for help when there is an emergency. 

The terminal device immediately uploads emergency alarm to monitoring center. Please take action to deal 

with the alarm quickly. 

 

3.3.20 Main power off alarm 

The terminal device will issue a power off warning in 3 seconds when the main power supply was cut off, 

at the same time start the backup battery (can last around 2 to 4hours), again automatically detect whether 

cancel the alarm after 30secounds. Center could confirm or cancel the alarm after alert received. The 

voltage detecting value of power off alarm <DC 7V 

 

3.3.21 Main power undervoltage alarm 

The  terminal  device  will  issue  undervoltage  warning  immediately  to  monitoring  center  while  the  main 

power suplly is undervoltage, at same time start the backup up battery(can last around 2 to 4hours). It will 

auto-check whether cancel the alarm or not 30s later. The undervoltage detecting value <DC9V.   

 

3.3.22 GPS antenna failure alarm 

The tracking device will report the GPS antenna failure alarm to monitoring center immediately when the 

GPS antenna is damaged, 

 

3.3.23 Illegal ignition warning 

User can set a time range that not premitted to start engine via montoring center. If the driver start engine 

within  the  prohibited  time,  the  tracking  device  will  report  illegal  ignition  warning  data  to  center. 

Monitoring center can confirm or cancel the alarm as well as disable the function. 

 

 

 

Summary of Contents for KL-P103

Page 1: ...GPS GSM fleet management tracking system www konlen com 1 18 GPS GPRS GSM vehicle tracker KL P103 USER MANUAL VER KL091005 ...

Page 2: ...g and tracking in real time Positioning call Track playback listen in Camera photo taking Mileage statistic Cut off the oil recovery circuit Overspeeding alarm Parking overtime alarm Fatigue driving alarm Idle time out alarm User self definiton alarm Emergency help alarm Main power off alarm Enter or exit the electronic fence alarm The designated route deviate warning GPS antenna short circuit ope...

Page 3: ... per customer s requirement Uploading picture speed 20s to 50s camera Support one rout of camera GSM Frequency 900MHz 1800 MHz 850MHz 1900 MHz GPS Module Latest U BLOX locating module GPS Sensitivity 159Dbm GPS Frequency Baud rate Receiving panel structure GPS module 24 channel Locating accuracy 5m 95 Time update Synchronize with GPS Cold start time 36s in average Heat start time 1 s in average LE...

Page 4: ...nal 1 4 Indicator light definition NOTE The line in green in chart means works normally and in standby status LED color Light on Light off Status description green 0 5s 0 5s In starting status green 1s 1 s Failed to search for GPS satellite signal unlocated green 5 s 0 5 s Found GPS satellite signals located green Light off Light off Device power failed or LED indicator light fault red 1 s 1 s Sea...

Page 5: ...ble color LED light 13 MIC connector 103A6A 6 Pin installation cable 103A3A For User self defined alarm one anode trigger and one cathode trigger and device updating 103A4A External device serial port support one rout of camera or overspeed alarm buzzer etc 2 2 SIM card installation A Take off the rear cover of main device by screwdriver B Install the SIM card as below steps Step 1 Step 2 Step 3 C...

Page 6: ...t the red wire and black wire with the car battery the main power Connect white wire with ACC for checking ACC status on or off The yellow wire with the Circuit Breaker for Oil cut off power off c Please install the emergency button in hiden place but convenience for driver to operate Make sure no any objects press the button or it will always send emergency alert to monitoring center d Please mak...

Page 7: ...t how to connect wired door contact with 103A3A green or red wire Note The 103A3A can also use for tracker updating 2 6 103A4A and camera installation The 103A4A is a serial port with 4Pin cables that can connect camera Factory will provide user a additional cable with connector each end One end connects with 103A4A the other end connect with camera Please choose the correct installation location ...

Page 8: ...re via GPRS c Add the GPS tracker into the software as per software manual then check whether the tracker is online If the tracker online that means all the set is correct and tracker is OK d Install the tracker in the vehicle as per installation instruction e After installation please check whether the tracker is online whether download and update the GPS data normally f Manage all the added GPS ...

Page 9: ... Status Enquiry AS1234STATE ID 99999999 VER V1 05 IP 119 147 23 108 7777 CEN AUT CSQ 19 GPS OK ACC ON GPRS 30 POWER ON NETTYPE GPRS 1 ID Current Device ID 2 Ver Current firmware version 3 IP Current IP and Port 4 CSQ Current GSM signal strength 5 GPS GPS available or not 6 ACC Current ACC status 7 GPRS Current GPRS data upload interval 8 POWER Current Power status 9 NETTYPE Current Communicate mod...

Page 10: ...ng Number AS1234LISTEN 13481944860 Device will phone to telephone nuber13481944860 10 SET Speed Limit AS1234SPEED 120 AS1234SPEED 0 ESPE 120 OK ESPE OFF OK 1 Unit km h 2 Type and range 0 cancel speed limit 11 User Defined Alarm 1 AS1234 DEFINED1 1 AS1234 DEFINED1 0 User defined1 ON OK User defined 1 OFF OK Value type 0 forbid 1 open The alarm information will only send to authorized Number and cen...

Page 11: ...PRS to link with internet and transmit GPS data to server Due to different countries and districts there are different APN for GPRS to LOG IN from different networks server agent Please consult your local provider for correct APN gateway network logon username and password then edit three SMS following NO 3 4 5 SMS format and send to trackers separately so as to make them get through with server E...

Page 12: ...motely modify password For safe please change trackers password timely by platform after the trackers work normally 3 3 4 Remotely restart tracker device User can issue restart command to reboot the device via monitoring platform when certain trackers work anormally 3 3 5 Remotely check the version No of terminal device Monitoring center can inquiry the trackers version remotely including terminal...

Page 13: ...nter according to designated interval distance That is linear distance which is caculated by longitude and langitue The factory default is 30meters adjustable range is 30 to 255m 3 3 9 Mileage statistics The GPS tracker can caculate the driving mileage and report to center management platform automaticlly Monitoring center can enquiry save and delete the mileage statistical data as per actual appl...

Page 14: ...utomatically The standby mode is mainly reflected in Turn off the GPS module power supply and out of GPRS mode temporarily Keep SMS mode In this mode the GPRS transmission and data updating slow down in order to saving the GPRS flow capacity The interval time of data transmission is changed to be about once an hour The trackers will automatically withdraw the standby sleeping mode when the ACC is ...

Page 15: ...nitor the vehicle movement position in real time as per preset region value that prohibit vehicle enter or leave When the vehicle mobile latitude and longitude value exceeds a user preset area value the enter or exit G fence alert data is reported to monitoring center The alarm is cancelled while vehicle return to the preset allowable value The Max G fence quantity user can draw is 25 no limit to ...

Page 16: ...ice immediately uploads emergency alarm to monitoring center Please take action to deal with the alarm quickly 3 3 20 Main power off alarm The terminal device will issue a power off warning in 3 seconds when the main power supply was cut off at the same time start the backup battery can last around 2 to 4hours again automatically detect whether cancel the alarm after 30secounds Center could confir...

Page 17: ... system www konlen com 17 18 Ⅳ Ⅳ Ⅳ Ⅳ appendix Brief instruction of GPS fleet management platform 4 1 The diagram of working principle Server installed with center software Clients monitoring center Vehicles GPS Satellite GPRS SMS CDMA ...

Reviews: