Warning:

 Make sure that the ends of the battery with positive and negative polarity are matched correctly, 

as  marked  in  the  battery  compartment.  If  the  battery  is  installed  incorrectly,  running  the  lock  will  not  be 
possible. 

There are locks supplied more than one battery, in such cases, replace all the batteries at the same time. Do 
not mix old and new batteries or mix batteries of different types (for example, alkaline and lithium batteries). 

Batteries  should  not  be  opened,  punctured,  loaded,  installed,  or  exposed  to  fire,  heat  or  water.  It  is 
recommended to only use alkaline or lithium batteries of known brands.   

 

Adjustment of hinges 

 

KP Strong Safes have external hinges.  

To make an adjustment you need two hex keys of size 4mm. 
 

 

 

Fig. 3 Upper hinge 

 

 

 

Adjustment of hinges is performed as follows: 

 

1.

 

Remove the plug (4) from the upper hinge.  

2.

 

Height adjustment of the door (2) is done by using the adjustment screw (3) by turning the hex key 

4mm. Lifting of the door is done by turning the screw clockwise. Lowering of the door is done by 
turning the screw (3) in the opposite direction.   

3.

 

Use glue to secure the thread from the unscrewing the screw (3). Before adjusting unscrew the 

adjustment screw (3) and apply onto the thread a few drops of thread glue (permanent joints) 

4.

 

Insert the plug into the hinge hole (4). 

 
Adjustments is performed so that the slots on the top and bottom of the door were equal (control  on half 
closed door of the safe). In case of problems, please contact the Service. 

 

Summary of Contents for Grade II

Page 1: ...Product card User manual KP Strong Safe Grade II KONSMETAL Export Department export konsmetal pl KONSMETAL Service phone 48 89 6253799 Monday Friday 8 16 e mail serwis konsmetal pl...

Page 2: ...Types of locks 5 Standard colors 5 Specifications 5 Installation of separately lockable internal box 7 Installation of shelves 8 Operation opening 8 Operation closing 9 Operation separately lockable i...

Page 3: ...default code on its own unknown to third parties BEFORE using the device Leaving default code is a threat to the security of deposited values Changing the code and test of the new code in the combina...

Page 4: ...lock with two keys Shelves with a suspension height adjustment maximum shelf load 50kg Clips for shelf mounting Perforations in the Strong Safe s bottom 28 mm Operating manual for the installed combin...

Page 5: ...KP Strong Safe grade II Types of locks key combination electronic Standard colors Light grey RAL 7035 Light grey RAL 9002 Black RAL 9005 Any color from the RAL palette to order powder coated Specific...

Page 6: ...rnal box Rotary handle H KP 67 1 YES 32 80 KP 100 2 YES 40 125 KP 120 3 YES 40 125 KP 150 4 YES 40 125 Can be mounted as additional equipment Separately lockable internal box External dimensions mm Do...

Page 7: ...ver the perforation with a plug If the Strong Safe is too small to drill a hole in the floor through the perforation in its bottom the drill does not fit into the Strong Safe or for example when inter...

Page 8: ...Turn the handle clockwise 4 Pulling the door opens the safe Opening of safes fitted with combination or electronic lock 1 Open the combination electronic lock following the steps described in the enc...

Page 9: ...the key to the lock and turn it to the right by more than 90 above 1 4 of a rotation 2 Box is opened after pulling the door outwards Box closing 1 Push the door against the box body 2 Rotate the key...

Page 10: ...battery is located in an external lock keyboard a Open the safe b Remove the black cover of the battery compartment located on the inside of the safe door c Replace the battery noting the polarity the...

Page 11: ...t of hinges KP Strong Safes have external hinges To make an adjustment you need two hex keys of size 4mm Fig 3 Upper hinge Adjustment of hinges is performed as follows 1 Remove the plug 4 from the upp...

Page 12: ...ituation signaling by the relevant model of the lock can be found in the lock manual WARNING Triple attempt of entering the wrong code moves the lock into punishment mode which means that the lock wil...

Reviews: