3 Operating and Maintenance

3.1 Unpacking and Inspection

Users, before installing and commissioning, shall first check

whether the appearance of the product is good, and

whether the variety and number of attachments is in line

with the list of accessories attached to the specifications. If

there is any defect, please contact the supplier or

manufacturer timely.

3.2 Preparations

1.

Open the cap.

2.

Add the correct amount of prescribed medication to

the medication cup.

3.

Cover the cap and connect the mouthpiece or mask.

Summary of Contents for 608D

Page 1: ...Read this manual carefully before use Manufacture date see the label Product life 5 years ir Compressing Nebulizer Model 608D User s manual Jiangsu Konsung Bio Medical Science and Technology Co Ltd A...

Page 2: ...ritten consent of Konsung any materials contained in this manual shall not be photocopied reproduced or translated into other languages Materials protected by the copyright law including but not limit...

Page 3: ...Konsung may provide with compensation necessary circuit diagrams and other information to help qualified technician to maintain and repair some parts which Konsung may define as user serviceable Cont...

Page 4: ...s 8 3 Operating and Maintenance 11 3 1 Unpacking and Inspection 11 3 2 Preparations 11 3 3 Nebulizing 13 3 4 Maintenance after use 15 4 Troubleshooting Guide 17 5 Warranty and Service 18 5 1 Warranty...

Page 5: ...absorbed in the patient s mouth throat trachea bronchi alveoli etc Mucosal absorption and achieve the purpose of treatment 1 2 Product specification 1 Maximum nebulization rate 0 2mL min 2 Residual v...

Page 6: ...it in environment where combustible anesthetic gases are mixed with air oxygen or nitro monoxide 17 Working mode Continuous 18 Normal working conditions Environmental temperature 5 C 35 C Relative hum...

Page 7: ...w 5 C apply the device only when the temperature meets normal operating conditions 1 3 Structure and working principle Air compressing nebulizer is composed by compressor housing and nebulizing kit wi...

Page 8: ...rking principle The compressed air generated with the pump inside the main unit when pumping out from the nozzle can suck up the medication with the negative pressure between the nozzle and the air tu...

Page 9: ...be operated by professionals 1 4 Product features 1 In normal use the atomized air flow is 3L min to 9L min flow rate is not adjustable The corresponding pressure is 60kPa to 150kPa 2 The atomization...

Page 10: ...tput air pressure and flow rate is 0 under the most unfavorable conditions 6 Main advantages of inhalation therapy Inhaled medication can reach the patient respiratory tract and lungs and deposit this...

Page 11: ...g documents Do not expose to open flames Caution Against Wet Fragile handle with care This side up Class II equipment ON power switched on Alternating current OFF power switched off Date of manufactur...

Page 12: ...ay cause symptoms to deteriorate 6 Do not use only water in the nebulizer for inhaling purposes 7 Do not use the device where it may be exposed to flammable gas 8 Do not use or store the device in hum...

Page 13: ...posed to humidity or direct sunlight 20 Provide close supervision when this device is used by on or near infants children or invalids 21 Do not put fingers or any other objects into the device Doing s...

Page 14: ...se oil detergent ect Neither use such materials and their analogue to the device Do not use the device in a confined space Operate the device at least 15cm away from the obstacles such as the walls an...

Page 15: ...is good and whether the variety and number of attachments is in line with the list of accessories attached to the specifications If there is any defect please contact the supplier or manufacturer time...

Page 16: ...exceed the maximum mark 3 The scale on the medication cup is for reference only Use the scale on your syringe or vial for accurate measurement of medication 4 After the medication is added to the med...

Page 17: ...ation cup 3 3 Nebulizing 1 Turn the power switch to the on position 2 As the main unit starts connect the air tube to the connector of the main unit and the medication cup respectively 3 Hold the nebu...

Page 18: ...nebulizing kit so the angle of the kit is greater than 45 degrees Medication may flow into the mouth and the spraying may be ineffective 3 If there is anything unusual in using please stop using it i...

Page 19: ...or oil and avoid the liquid into main unit during cleaning The nebulizer should be dust proof and moisture proof during deactivation It is best cleaned every three months NOTE 1 Dispose of the device...

Page 20: ...s been used on average for more than 500 hours replace it with a new one 1 Remove filter cover from the front side of nebulizer 2 Remove the dirty filter sheet 3 Insert a new filter sheet 4 Put the fi...

Page 21: ...he medication cup Add the correct amount of prescribed medication to the medication cup The nebulizing kit has been deformed in disinfection Replace the nebulizing kit The nebulizing kit has been bloc...

Page 22: ...or return and replacement of the product which does not meet product standards In the normal condition of usual use and storage the company is responsible for free repair and replacement if the device...

Page 23: ...oper use of the product If you have any questions please contact us NOTE 1 Please take care of the purchase invoice and maintenance card for service 2 The non controllable factor or the artificial dam...

Page 24: ...its maximum length is 1 5 meter WARNING 1 Use of cables and transducers other than those specified with the exception of cables and transducers sold by the manufacturer of the medical electrical equi...

Page 25: ...that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance 6 2 Electromagnetic immunity The device is...

Page 26: ...ercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT for 0 5 cycle 95 dip in UT 40 UT for 5 cycles 60 dip in UT 70 UT...

Page 27: ...nd the device as recommended below according to the maximum output power of the communications equipment The device is intended for use in the electromagnetic environment specified below The customer...

Page 28: ...nded separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency range b Inte...

Page 29: ...operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the device Over the frequency range 150kHz to 80MHz field strengths should be less...

Page 30: ...r Note 1 From 80MHz to 800MHz the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from struc...

Page 31: ...nd Technology Co Ltd Address NO 8 Shengchang West Road Danyang Development Zone Jiangsu Province 212300 P R China Tel 86 511 86375968 WhatsApp 0086 18952012596 mail info konsung com Website www konsun...

Reviews: