background image

www.kontron.com

CP6924-1-RA-A

Document Revision 1.1
Date: November, 2015

User Guide

Summary of Contents for CP6924

Page 1: ...www kontron com CP6924 1 RA A Document Revision 1 1 Date November 2015 User Guide...

Page 2: ...ht 2015 Kontron AG All rights reserved All data is for information purposes only and not guaranteed for legal purposes Infor mation has been carefully checked and is believed to be accurate however no...

Page 3: ...Technical Specification 14 1 2 1 Power Requirements 14 1 2 2 Mechanics 14 1 2 3 Temperature 14 1 2 4 Humidity 14 1 2 5 Altitude 14 1 2 6 Vibration 14 1 2 7 Shock 14 1 2 8 Safety 15 1 2 9 Electromagne...

Page 4: ...uting 38 4 1 5 FASTPATH Quality of Service 39 4 1 6 FASTPATH Multicast 40 4 2 Supported MIBs 40 4 2 1 Enterprise MIB 40 4 2 2 Base Package MIBs 40 4 2 3 Switching Package MIBs 41 4 2 4 Routing Package...

Page 5: ...www kontron com CP6924 1 RA A User Guide 5 5 Thermal Considerations 69 6 Power Considerations 71 6 1 Baseboard 71 6 2 Backplanes 71...

Page 6: ...HPM 1 Commands 50 Table 4 6 Kontron OEM Commands 51 Table 4 7 Sensor List 56 Table 4 8 IPMB Link Type C3h Reading 58 Table 4 9 IPMB Link Type C3h Event Message 59 Table 4 10 MMC Reboot Type 24h Readin...

Page 7: ...www kontron com CP6924 1 RA A User Guide 7 List of Figures Figure 3 1 CP6924 1 RA A Functional Block Diagram 24 Figure 5 1 Position of Temperature Sensors Top Side View 69...

Page 8: ...nufactured to satisfy environmental protection requirements where possible Many of the compo nents used structural parts printed circuit boards connectors batteries etc are capable of being recycled F...

Page 9: ...This symbol indicates that the product described in this manual is in compliance with all applied CE standards Please refer also to the section Regulatory cpmpli ance Statements in this manual WARNING...

Page 10: ...plastics or sponges They can cause short circuits and damage the batteries or conduc tive circuits on the system Laser Lights Laser light from fiber optic transmission cables and components can damage...

Page 11: ...removed will also be excluded from this warranty If the customer s eligibility for warranty has not been voided in the event of any claim he may return the product at the earliest possible convenience...

Page 12: ...ase T Transceiver with SGMII Ports 24x 10 100 1000Base T via MII interface to backplane connector J5 J4 and J3 BCM56334 Switch manages transceiver via MIIM0 Interface LED BUS connects to CPLD Switch s...

Page 13: ...p core voltages 1 1 1 5 Miscellaneous JTAG Boundary Scan support Board layout is prepared for conduction cooling All parts are extended temperature range parts 40 C to 85 C or better 1 1 2 General com...

Page 14: ...oards are designed to meet the following requirements Operating 4000m 13123 ft Check for onboard peripherals if applicable Non Operating 15000 m 49212 ft 1 2 6 Vibration The CP6924 1 RA A board is des...

Page 15: ...e EN61000 6 3 Europe EN61000 6 2 Europe VCCI Voluntary Japan Electromagnetic Compatibility requirement EN 300 386 Electro Magnetic Compatibility EMC Requirements for Public Telecommunication Network E...

Page 16: ...negotiation of speeds and operational mode on all external copper GE in terfaces as well as on all base fabric interfaces Layer 2 multicast services using GARP GMRP IEEE 802 1p VLAN support including...

Page 17: ...starts Support for retrieving and installing multiple configurations Support for startup configurations based on the cPCI SGA GA Shelf Geograph ical Address Geographical Address see CP6924 CLI Referen...

Page 18: ...ving the CP6924 The SFP cages have sharp edges which might lead to injuries ESD Sensitive Device The CP6924 board contains electrostatically sensitive devices Please observe the necessary precautions...

Page 19: ...ents are observed 2 Ensure that the board is properly configured for operation in accordance with application requirements before in stalling For information regarding the configuration of the CP6924...

Page 20: ...board from the system refer to the system manual 2 4 Software Installation The CP6924 comes as a pre installed system with all necessary OS filesystem drivers and applications factory installed with...

Page 21: ...The Gigabit Ethernet serviceport on the CP6924 front plate has no IP address set by default it is necessary to assign an IP address statically or enable dhcp on the serviceport Because the required c...

Page 22: ...d configuration steps are done in the CLI an initial access using the serial port is required The procedure for assigning an IP address to the network port is described in the following User input is...

Page 23: ...e you sure you want to save y n y Config file current startup config created successfully Configuration Saved Ethernet Fabric To access the CLI via Gigabit Ethernet networkport open a telnet connectio...

Page 24: ...e 24 3 Functional Description This chapter describes the board specific items of the CP6924 1 RA A The base board is a standard Fabric 6U CompactPCI Gigabit Ethernet Switch with 24 channels Figure 3 1...

Page 25: ...er with EDC BSC Master I2C for SFP support SPI FLASH programming interface LED BUS connects to CPLD Switch supports JTAG Boundary Scan The ports of the switch are mapped as shown in the following tabl...

Page 26: ...telligent devices to monitor events and to log events to a central repository intelligent FRU Field Replaceable Unit The Peripheral Manager is a 32 bit microcontroller with on chip memory of 2 Mbyte F...

Page 27: ...2 Current sensors The current of the backplane voltages can be measured by the Peripheral Manager internal A D converters AD0_4 and AD0_5 The current is measured indirectly by the voltage drop of the...

Page 28: ...either 3 3 V or 5 V No keying is required on J1 which designates universal V I O The CP6924 is compatible with all standard 6U CompactPCI passive backplanes with rear I O support on the system slot F...

Page 29: ...NC GND 20 NC GND V_IO_CPCI NC NC GND 19 V_3V3_CPCI NC NC GND NC GND 18 NC GND V_3V3_CPCI NC NC GND 17 V_3V3_CPCI IPMB0_SCL IPMB0_SDA GND NC GND 16 NC GND V_IO_CPCI NC NC GND 15 V_3V3_CPCI NC NC CPCI_...

Page 30: ...NC NC NC NC NC GND 19 NC NC IPMB1_SDA IPMB1_SCL IPMB_ALERT GND 18 NC NC NC NC NC GND 17 NC NC NC NC NC GND 16 NC NC NC NC NC GND 15 NC NC NC NC NC GND 14 NC NC NC NC NC GND 13 NC NC NC NC NC GND 12 N...

Page 31: ...ND FL_DC8 FL_DC8 GND 15 FL_DB8 FL_DB8 GND FL_DD8 FL_DD8 GND 14 FL_DA7 FL_DA7 GND FL_DC7 FL_DC7 GND 13 FL_DB7 FL_DB7 GND FL_DD7 FL_DD7 GND 12 FL_DA6 FL_DA6 GND FL_DC6 FL_DC6 GND 11 FL_DB6 FL_DB6 GND FL...

Page 32: ..._DD GND 23 FL21_DA FL21_DA GND FL21_DC FL21_DC GND 22 FL21_DB FL21_DB GND FL21_DD FL21_DD GND 21 FL22_DA FL22_DA GND FL22_DC FL22_DC GND 20 FL22_DB FL22_DB GND FL22_DD FL22_DD GND 19 FL23_DA FL23_DA G...

Page 33: ...L_DA19 FL_DA19 GND FL_DC19 FL_DC19 GND 21 FL_DB19 FL_DB19 GND FL_DD19 FL_DD19 GND 20 FL_DA18 FL_DA18 GND FL_DC18 FL_DC18 GND 19 FL_DB18 FL_DB18 GND FL_DD18 FL_DD18 GND 18 FL_DA17 FL_DA17 GND FL_DC17 F...

Page 34: ...FASTPATH Management Core Features RFC 854 Telnet RFC 855 Telnet option specifications RFC 1155 SMI v1 RFC 1157 SNMP RFC 1212 Concise MIB definitions RFC 1867 HTML 2 0 forms with file upload extensions...

Page 35: ...at RFC 4419 Diffie Hellman group exchange for the SSH transport layer protocol HTML 4 0 specification December 1997 Java Plug in 1 6 0_01 and Java Script 1 3 Advanced Management Features Industry stan...

Page 36: ...RFC 5171 UniDirectional Link Detection UDLD Protocol Additional Layer 2 Functionality Broadcast storm recovery Double VLAN VMAN tagging DHCP Snooping Dynamic ARP inspection Independent VLAN Learning...

Page 37: ...rotocol support RFC 2869 RADIUS extensions RFC 28869bis RADIUS support for Extensible Authentication Protocol EAP RFC 3164 The BSD syslog protocol RFC 3580 802 1X RADIUS usage guidelines RFC 5176 Dyna...

Page 38: ...s autoconfiguration RFC 2464 IPv6 over Ethernet RFC 2711 IPv6 router alert RFC 3056 Connection of IPv6 Domains via IPv4 Clouds RFC 3315 Dynamic Host Configuration Protocol for IPv6 DHCPv6 RFC 3484 Def...

Page 39: ...ns for inbound or outbound layer 2 traffic classification based on Source MAC address Destination MAC address EtherType VLAN identifier value or range outer and or inner VLAN tag 802 1p user priority...

Page 40: ...iguration 4 2 Supported MIBs The Software supports the following MIBs 4 2 1 Enterprise MIB Support for all managed objects not contained in standards based MIBs 4 2 2 Base Package MIBs RFC 2273 SNMP N...

Page 41: ...02 1AB 2005 LLDP EXT DOT3 MIB ANSI TIA 1057 LLDP EXT MED MIB POWER ETHERNET MIB Draft no RFC DIFFSERV DSCP TC Draft no RFC FASTPATH Greenethernet Private MIB RFC 2677 IANA Address Family Numbers MIB R...

Page 42: ...vices FASTPATH MVRP MIB MVRP private MIB for IEEE 802 1Q devices FASTPATH Enterprise MIBs supporting switching features Broadcom Private MIB for 802 1Qat 802 1Qav Configuration 4 2 4 Routing Package M...

Page 43: ...ddress extended management features Kontron specific MIBs start with a kex_ Here s a list of MIBs provided in this example for release GA 2 0 including its content kex_config Set BSP startup services...

Page 44: ...st import the MIBs into the MIB browser The MIBs are provided on demand for current releases SNMP can also be used for updating System Software IPMI FW and PLD 4 3 Bootloader On the CP6924 1 RA A Ethe...

Page 45: ...ence of onboard I2C devices PCI Express Check for PCI Express switch device presence Serviceport Onboard PPC405EX ethernet internal loopback test Bootloader environment Check for valid bootloader envi...

Page 46: ...startup script for board firmware rollback from backup partition after a CRC checksum error has been detected check bootsource Script check for user defined bootcmd bootargs pair check rollback Scrip...

Page 47: ...ntrols POST memory test execution 0 only data and address line test is executed 1 fast memory test with checkerboard pattern tests 4MB of memory divided on different 128kB memory chunks 2 full memory...

Page 48: ...ar_env itself was not changed run clear_env 4 3 3 Bootloader Pushbutton Reset When the pushbutton is pressed the CP6924 1 RA A glue logic performs a SysReset to the CPU After reset has been issued the...

Page 49: ...tervals to ensure continuity of operation of the board s management subsystem The MMC watchdog supervisor does not reset the payload power and the restart of the MMC will not affect the payload The ex...

Page 50: ...d 35 9 S E 27h O Yes Set Sensor Event Enable 35 10 S E 28h O Yes Get Sensor Event Enable 35 11 S E 29h O Yes Get Sensor Reading 35 14 S E 2Dh M Yes FRU Device Commands M Get FRU Inventory Area Info 34...

Page 51: ...Status HPM 1 37h YES Initiate Manual Rollback HPM 1 38h YES Table 4 6 Kontron OEM Commands Command NetFn LUN Code OemApSetControlState 3Eh 0 20h OemApGetControlState 3Eh 0 21h OemApGetFirmwareSysUpTim...

Page 52: ...rsion 1 5 7 Additional Device Support 7 1b device does implement chassis device support 6 0b device does not implement bridge device support 5 1b device generates event messages onto the IPMB 4 1b dev...

Page 53: ...ice FRU Inventory Device IPMB Event Receiver IPMB Event Generator Chassis Device Aux Firmware Rev Info 0x00 0x02 0x03 0x00 OemApFormatStorage Command This command re formats the I2C EEPROM attached to...

Page 54: ...to the register interface provided by the glue logic attached to the MMC LUN NetFn CMD oemApSetNvData 3 OEM 3Eh 0Fh Byte Data Field Request data 1 Pass Code 0 K 2 Pass Code 1 o 3 Pass Code 2 n 4 Pass...

Page 55: ...lds hysteresis event generation capabilities etc that specify the sensor s behavior Some fields of the sensor SDR are configurable through IPMI v1 5 command and are set to a built in initial value Mod...

Page 56: ...11 10 Sxx V_3V3 01h Voltage Payload Voltage 12 11 Sxx V_3V3_SUS 01h Voltage Suspend Voltage 13 12 Sxx V_3V3_CPLD 01h Voltage Suspend CPLD Voltage 14 13 Sxx V_3V3_CPCI 01h Voltage CPCI Voltage 15 14 Sx...

Page 57: ...5 000 85 000 95 000 6 S02 V_1V0 1 028 Volts ok na na na 75 000 85 000 95 000 7 S02 V_1V2 1 198 Volts ok na na 75 000 85 000 95 000 8 S02 V_1V25 1 277 Volts ok na na na na na na 9 S02 V_1V8 1 880 Volts...

Page 58: ...control state MMC determines state of the bus 2 0 IPMB L Local State 0h no failure bus enabled 1h unable to drive clock high 2h unable to drive data high 3h unable to drive clock low 4h unable to driv...

Page 59: ...ode in Event Data 2 and 3 3 0 Offset 00h IPMB L disabled 01h IPMB L enabled All other values are reserved 6 Event Data 2 7 0 Reserved read as zero 7 Event Data 3 7 4 Reserved read as zero 3 IPMB L Ove...

Page 60: ...4h Event Message Offset Request data 1 Event Message Rev 04h 2 Sensor Type 24h Platform Alert 3 Sensor Number 4 7 Event Direction 1b Deassertion 0b Assertion 6 0 Event Type 03h digital discrete 5 Even...

Page 61: ...vent Message Offset Request data 1 Event Message Rev 04h 2 Sensor Type C7h OEM Firmware Upgrade 3 Sensor Number 4 7 Event Direction 1b Deassertion 0b Assertion 6 0 Event Type 6Fh sensor specific 5 Eve...

Page 62: ...re Error POST Error 5 80h ignore on read Table 4 15 POST Fail Type 0Fh Event Message Offset Request data 1 Event Message Rev 04h 2 Sensor Type 0Fh System Firmware Progress POST Error 3 Sensor Number 4...

Page 63: ...g from flash 5 80h ignore on read Table 4 17 Boot Fail Sensor Type 1Eh Event Message Offset Request data 1 Event Message Rev 04h 2 Sensor Type 1Eh Boot Error 3 Sensor Number 4 7 Event Direction 1b Dea...

Page 64: ...T 0 86V 0 882V 0 9V 0 918V 0 94V Sxx V_1V0 0 95V 0 98V 1 0V 1 02V 1 05V Sxx V_1V2 1 16V 1 176V 1 2V 1 224V 1 24V Sxx V_1V25 1 2V 1 225V 1 25V 1 275V 1 3V Sxx V_1V8 1 7V 1 764V 1 8V 1 872V 1 9V Sxx V_2...

Page 65: ...Supported are the following FRU data areas and data fields shown values are examples which may differ depending on the used board typ FRU Board Info Area Manufacturing date time Board manufacturer KO...

Page 66: ...8 KB 128 F8180000 180000 43264 mtd3 system Linux system kernel and ini trd multi image FABC0000 2BC0000 10240 mtd4 config Read Write Configuration data FB5C0000 35C0000 10240 mtd5 profiles Storage for...

Page 67: ...system is a verbatim copy of active system and is stored in flash partition mtd5 as a whole This allows flash recovery from the redundant system in case that update fails due to power loss or similar...

Page 68: ...tive backup Copying active image to backup image Ethernet Fabric The image will be copied including the configuration settings currently stored for active image 4 5 2 Updating IPMI Firmware Updating t...

Page 69: ...4 itself does not provide any active means of temperature regulation As long as the temperature values stay below their upper critical threshold all components on the CP6924 are considered to be opera...

Page 70: ...atures of on board components stay below their critical thresholds Note The holdup time of the real time clock all CP6924 versions is up to 6 days under moderate storage temperature conditions It may...

Page 71: ...tings Power consumption below 50 W 5 0 V VIN 5 3 designed for maximum load 8A 40W 3 3V PoL Converter 1 25V PoL Converter 1 00V PoL Converter 3 3 V VIN 5 3 designed for maximum load 10A 33W 2 5V PoL Co...

Page 72: ...Asia Pacific 17 Building Block 1 ABP 188 Southern West 4th Ring Road Beijing 100070 P R China Tel 86 10 63751188 Fax 86 10 83682438 info kontron cn User Guide All data is for information purposes only...

Reviews: