www.kontron.com
CP6924-1-RA-A User Guide
61
MMC FwUp (Type C7h)
Table 4-12:
MMC FwUp (Type C7h) Reading
Offset
Request data
1
Sensor Number
Response data
1
Completion Code
2
Sensor Reading
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
3
Standard IPMI Byte. (See “Get Sensor Reading in the IPMI Specification)
4
00h - ignore on read
5
80h – ignore on read
Table 4-13:
MMC FwUp (Type C7h) Event Message
Offset
Request data
1
Event Message Rev
04h
2
Sensor Type
C7h – OEM Firmware Upgrade
3
Sensor Number
4
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
6Fh = sensor specific
5
Event Data 1
[7:4] – 0h = no data in Event Data 2 and 3
[3:0] – Offset
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
6
Event Data 2
FFh = not specified
7
Event Data 3
FFh = not specified
Response data
1
Completion Code
SDR Configuration
Value
Description
Assertion Event Mask
01h
Offset 0 can generate an assertion event
Deassertion Event Mask
00h
Sensor cannot generate deassertion events