background image

MSP8040 Series User Guide Rev. 1.2 

 

 

www.kontron.com 

// 11 

 

1.3.

 

PCI Mapping 

Table 1: PCI mapping 

Bus:Device. 
Function 

Device 
ID 

Component 

Description 

Note 

CPU 

00:00.0 

6F00  Host bridge 

Intel Corporation Broadwell DMI2 (rev. 01)

 

Intel XEON D-15xx processor

 

00:03.1 

6F09  PCI bridge 

Intel Corporation Broadwell PCI Express Root Port 3 
(rev. 01)

 

NVMe port

 

00:03.3 

6F0b  PCI bridge 

Intel Corporation Broadwell PCI Express Root Port 3 
(rev. 01)

 

NVMe port

 

Chipset 

00:16.0 

8C3A 

Communication 
controller 

Intel Corporation 8 Series/C220 Series Chipset Family 
MEI Controller No.

 

1 (rev. 04) 

Broadwell-DE integrated 
chipset 

00:1c.0 

8C10  PCI bridge 

Intel Corporation 8 Series/C220 Series Chipset Family 
PCI Express Root Port No.

 

1 (rev. d5) 

 

00:1c.5 

8C1A  PCI bridge 

Intel Corporation 8 Series/C220 Series Chipset Family 
PCI Express Root Port No.

 

6 (rev. d5) 

 

00:1c.6 

8C1C  PCI bridge 

Intel Corporation 8 Series/C220 Series Chipset Family 
PCI Express Root Port No.

 

7 (rev. d5) 

 

00:1d.0 

8C26  USB controller 

Intel Corporation 8 Series/C220 Series Chipset Family 
USB EHCI No.

 

1 (rev. 05) 

 

00:1a.0 

8C2D  USB controller 

Intel Corporation 8 Series/C220 Series Chipset Family 
USB EHCI No.

 

2 (rev. 05) 

 

00:1f.0 

8C54  ISA bridge 

Intel Corporation 8 Series/C220 Series Chipset Family 
Desktop Super SKU LPC Controller (rev. 05) 

 

00:1f.2 

8C02  SATA controller 

Intel Corporation 8 Series/C220 Series Chipset Family 
6-port SATA Controller 1 [AHCI mode] (rev. 05) 

 

00:1f.3 

8C22  SMBus 

Intel Corporation 8 Series/C220 Series Chipset Family 
SMBus Controller (rev. 05) 

 

Network devices 

0b:00.0

 

1537 

Ethernet 
controller 

Intel Corporation (rev. 03) 

Intel I210-IS 1Gb Ethernet to 
hub 1 

0b:00.0

 

1537 

Ethernet 
controller 

Intel Corporation (rev. 03) 

Intel I210-IS 1Gb Ethernet to 
hub 2 

BMC 

06:00.0

 

0013  PCI bridge 

Renesas Technology Corp. SH7757 PCIe Switch [PS] 

Renesas SH7757 BMC 

07:00.0

 

0013  PCI bridge 

Renesas Technology Corp. SH7757 PCIe Switch [PS] 

 

07:01.0

 

0013  PCI bridge 

Renesas Technology Corp. SH7757 PCIe Switch [PS] 

 

08:00.0

 

0012  PCI bridge 

Renesas Technology Corp. SH7757 PCIe-PCI Bridge 
[PPB] 

 

09:00.0

 

0534 

VGA compatible 
controller 

Matrox Electronics Systems Ltd. G200eR2 

Video controller of the remote 
access 

Network devices 

03:00.0 

15AB 

Ethernet 
controller 

Intel® Ethernet Connection X552 10GbE Backplane 

Intel X552 1Gb/10Gb to hub 1

 

03:00.1 

15AB 

Ethernet 
controller 

Intel® Ethernet Connection X552 10GbE Backplane 

Intel X552 1Gb/10Gb to hub 2

 

 

 

Summary of Contents for MSP8040 Series

Page 1: ... USER GUIDE MSP8040 Series Doc Rev 1 2 Objet ...

Page 2: ...tion will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this manual only contains a general description of processes and instructions which may not be applicable in every individual case In cases of doubt please contact Kontron This manual is protected by copyright All rights are reserved by Kontron No part of this document may be...

Page 3: ...ay 20 1 2 Added Xeon D 1559 support information 2016 Oct 04 Customer Service Visit our website at www kontron com Customer Comments If you have any difficulties using this guide discover an error or just want to provide some feedback please send a message to Kontron Detail any errors you find We will correct the errors or problems as soon as possible and post the revised user guide on our website ...

Page 4: ...e to observe the precautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the High Voltage Safety Instructions portion below in this section ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive to static electricity Care must therefore be taken during all...

Page 5: ...serting a Node Module 21 2 1 Extracting a Node Module 21 2 2 Inserting a Node Module 22 2 3 System Behavior upon Hot Swap 22 3 Software Configurations and Conventions 23 4 Configuring Node Modules 24 4 1 Node Reset 24 4 2 Boot Order 24 4 3 Boot from Virtual Media 25 4 4 OS Installation 25 5 Performing Updates 26 5 1 Processor Node Update 26 5 2 One Click Upgrade to Update all Nodes 26 Appendix A S...

Page 6: ...anagement Controller BP Backplane CLI Command Line Interface DMI Desktop Management Interface ECC Error Checking and Correction HHHL Half height half length HPM PICMG Hardware Platform Management specification family IOL IPMI Over LAN IPMI Intelligent Platform Management Interface KCS Keyboard Controller Style KVM Keyboard Video Mouse MEI Management Engine Interface NCSI Network Communications Ser...

Page 7: ...cement of any part assembly or sub assembly at their own discretion or to refund the original cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new o...

Page 8: ... node has one CPU engine MSP804x references through this guide refer to any variants of this Node Series as described in Table 2 Node key components unless specified otherwise MSH89xx references through this guide refer to any variants of the SYMKLOUD Hub Series e g MSH8900 MSH8910 unless specified otherwise An OS must be loaded on the processor nodes for the system to be operational Figure 1 SYMK...

Page 9: ...9 Figure 2 MSP804x in rear of chassis For information on other SYMKLOUD MS2910 components refer to the specific component s user manual To obtain the latest document version or to consult other SYMKLOUD documents visit the Kontron portal at kontron com ...

Page 10: ...MSP8040 Series User Guide Rev 1 2 www kontron com 10 1 2 Block Diagram Figure 3 MSP804x block diagram ...

Page 11: ...oration 8 Series C220 Series Chipset Family USB EHCI No 2 rev 05 00 1f 0 8C54 ISA bridge Intel Corporation 8 Series C220 Series Chipset Family Desktop Super SKU LPC Controller rev 05 00 1f 2 8C02 SATA controller Intel Corporation 8 Series C220 Series Chipset Family 6 port SATA Controller 1 AHCI mode rev 05 00 1f 3 8C22 SMBus Intel Corporation 8 Series C220 Series Chipset Family SMBus Controller re...

Page 12: ...ork connections 2 Intel I210 IS 1GbE controllers 1 Intel dual 10GbE controller integrated in SOC Security Optional TPM 2 0 SLB9660 TT2 0 Storage Onboard M 2 42 mm or 60 mm SATA module I O devices 1 serial port through backplane and hub or through SOL via the integrated BMC 1 KVM Keyboard Video Mouse accessible over LAN 1 USB storage via virtual media over LAN 1 micro USB connection in faceplate BI...

Page 13: ... the user guide of the hub used in the platform for information on system behavior upon hot swap Power consumption May vary depending on CPU and riser options MSP804x 80 W without storage or PCIe option Dual SATA storage adds up to 20 W PCIe option power budget is 50 W The maximums are typical Tests were conducted with CPU D 1548 128 GB of 2133 MHz DDR4 RDIMMs running a combination of CPU memory s...

Page 14: ...wer green Status amber Identify command in progress Blinking1 Not affected Not affected Payload power ON OFF ON ON not healthy OFF healthy Payload power OFF ON OFF ON not healthy OFF healthy 1 Fast blink 1 Hz 50 Power button State Short press Long press 4 seconds Power OFF Powers ON the CPU engine Nothing happens Power ON Performs a clean shutdown of the CPU engine Turns the CPU off immediately ...

Page 15: ...et to 1GbE for a link to be established with all four ports If the speed is set to 10GbE no link will be established with F1 and F2 see Table 5 For a complete port mapping and network topology of the system refer to the hub user guide Node used with hub MSH8910 When used with hub MSH8910 no matter the slot the MSP804x is installed in two 1GbE ports B1 and B2 and two 10GbE ports F1 and F2 are avail...

Page 16: ...the same subnet as that of the SYMKLOUD components as no default gateway is configured The default IOL IP addresses are shown in Figure 5 Figure 5 Default IP addresses The MSP804x nodes have a KVM functionality that allows users remote access to the CPU engine The remote console redirects the screen keyboard and mouse of the remote host system Through media redirection users can mount a device e g...

Page 17: ... The configuration sections of this document detail the availability of such calls for specific configurations Refer to the API documentation available from the SM To access SOL from the SM dashboard Console Access o Log in to the SM o From the Console Access dropdown list of the Dashboard screen select a platform o Log in with username console and password admin o When prompted enter the number o...

Page 18: ...P address of the hub to access the SM 3 From the Dashboard screen click on REMOTE ACCESS 4 Click on Node n under the platform in which the node is installed 5 Click on REMOTE ACCESS to start the session In the examples above the IP addresses of the SM Shared IP and or ShMC IP and the target node BMC IP must be in the same subnet 1 7 2 Serial Console Connection The serial interface of the hubs incl...

Page 19: ...OST and configuration menu redirection is VT100 The ASCII control code for Ctrl g is 7 To type Ctrl gg use the Ctrl g ASCII control code twice in a row Example of a serial connection to the node CPU serial console OS 1 Connect a PC s serial port to the active hub s console port 2 Establish a connection using the PC terminal emulator with parameters 115200 8n1 3 To configure the hub console port MU...

Page 20: ...1 2 www kontron com 20 1 7 3 Default User Names and Passwords Table 6 Default usernames and passwords Configuration interface Username and password SM UI admin admin ShMC CLI admin admin Node CPU serial console OS Customer specific ...

Page 21: ...ap procedures 1 Press the power button of the node to be extracted The power button should be configured in the operating system so it performs a clean shutdown when pressed 2 The ID LED of the node becomes steady blue the node is ready to be extracted 3 To extract the node module from the slot pull on the handle while pressing the safety lock Figure 8 towards the left Figure 8 Processor node modu...

Page 22: ...t for the power LED of the processor node module to become steady green 30 to 120 seconds the node is powered on and ready to use 2 3 System Behavior upon Hot Swap The system is electrically designed to support a surprise extraction However this type of extraction is not recommended and could affect system performance and functionalities When a hot swap procedure is performed on MSP804x nodes the ...

Page 23: ...lements in blue italics are configuration options or types The symbol separates a series of operations required to access a specific element Refer to the user guide of the hub used for the IPMI mapping of the system Configuration command tables Sections 4 and 5 contain tables with two columns The first column describes steps that can be performed in the web type interface s named in the header The...

Page 24: ...de reset section 4 1 Press Del or F2 when prompted to enter the bios setup menu Select the Boot tab to display the current boot order To choose the Boot Option Priority Use the up or down arrow key to select a boot device Press Enter to select the device to position Select the Save Exit tab Select Save Changes and Reset Perform a node reset section 4 1 Press Del or F2 when prompted to enter the bi...

Page 25: ... 30 seconds issue the following command to reset the payload PROMPT power reset The possible values for device are none Do not change boot device order pxe Force PXE boot cdrom Force boot from CD DVD bios Force boot into BIOS Setup floppy Force boot from Floppy primary removable media Notes You could boot from LAN from virtual media or from disk on board 4 3 Boot from Virtual Media To boot a proce...

Page 26: ...E Select the proper zip file Click on Open Wait for the transfer to finish Click on START UPGRADE API calls available to update a node Notes This operation must be done for all nodes 5 2 One Click Upgrade to Update all Nodes To update the firmware of the node BMC BIOS and FPGA of all nodes sequentially SM Not possible from a CLI type interface Dashboard OnClick Upgrade Click on bundle settings Cli...

Page 27: ...SPD 8 Temp DIMM C DIMM C Temperature via SPD 9 Temp DIMM D DIMM D Temperature via SPD 10 Temp PCIe Slot PCIe slot temperature 11 Vcc 12V IN 02h Voltage 01h Threshold Based Voltage on board 12V suspend power supply See IPMI v2 0 table 42 2 for threshold based event 12 Vcc 5V SUS Voltage on board 5V suspend power supply 13 Vcc 3 3V SUS Voltage on board 3 3V suspend power supply 14 Vcc 1 7V SUS Volta...

Page 28: ...type code C0h Kontron OEM Firmware Info forsensor definition and Event Reading type code 70h Kontron OEM Internal Diagnostic 36 IPMI Info 2 37 IPMI Watchdog 23h Watchdog 6Fh Sensor Specific IPMI Watchdog payload watchdog Only offset 0 1 2 3 8 are used See IPMI v2 0 table 42 3 Sensor type code 23h Watchdog 2 for sensor definition 38 POST Value C6h OEM POST Value 6Fh Sensor Specific Show current pos...

Page 29: ... State 10h Event Logging Disable 6Fh Sensor Specific Specify the status of the SEL Cleared Almost full Full Only offset 2 4 5 are used See IPMI v2 0 table 42 3 Sensor type code 10h Event Log Disable for sensor definition 47 SEL Time Set 12h System 6Fh Sensor Specific Specify when SEL time change Only offset 5 is used See IPMI v2 0 table 42 3 Sensor type code 12h for sensor definition 48 Jumper Sta...

Page 30: ... 0Eh 0Fh 5V 1 05V_SUS 0 75V_SUS 1 25V_SUS 1 5V_SUS 3 3V_SUS Combined 3 3V_SUS 1 5V_SUS 1 25V_SUS 0 75V_SUS 12V Slot Vcore 1 3V_SUS 1 7V_SUS 2 5V_Vpp VttDdr VddqDdr Unused Unused Jumper Status 6Fh Standard IPMI sensor specific D3h Kontron OEM Jumper Status Sensor 00h 01h 02h 03h 04h 05h 06h Jumper 00 Present JP4 1 2 Jumper 01 Present JP4 3 4 Jumper 02 Present JP4 5 6 Jumper 03 Present JP4 7 8 Jumpe...

Page 31: ...rammable Watchdog cold warm or forced cold 08h Software Initiated soft cold warm of forced cold 09h Setup Reset Software Initiated Cold 0Ah Power Cycle Full Reset Global Platform Reset FFh Unknown Health Status 7Fh OEM Health Severity Status Sensor 24h Platform Alert 00h Status not available in current state 01h Healthy 02h Informational fault 03h Minor fault 04h Major fault 05h Critical fault Eve...

Page 32: ...them to focus on their core competencies by offering a complete and integrated portfolio of hardware software and services designed to help them make the most of their applications With a significant percentage of employees in research and development Kontron creates many of the standards that drive the world s embedded computing platforms bringing to life numerous technologies and applications th...

Reviews: